网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
“STAND BY POWER”电门位于:()
- A、驾驶舱电源控制面板P5-5上
- B、驾驶舱主断路器面板P6
- C、驾驶舱左负载控制中心面板P18
- D、外电源P19面板
参考答案
更多 ““STAND BY POWER”电门位于:()A、驾驶舱电源控制面板P5-5上B、驾驶舱主断路器面板P6C、驾驶舱左负载控制中心面板P18D、外电源P19面板” 相关考题
考题
正常情况下,加油面板的工作电源如何接通()?
A、将”POWER”电门扳到”ON”位B、将”电瓶”电门扳到”ON”位C、将加油面板上的”油量测试和加油”电门扳到”辅助加油电源”位D、面板打开时,电源自动接通
考题
In which situation do the Rules require both vessels to change course ?______.A.Two power-driven vessels meeting head-onB.Two power-driven vessels crossing when it is apparent to the stand-on vessel that the give-way vessel is not taking appropriate actionC.Two sailing vessels crossing with the wind on the same sideD.All of the above
考题
当STAND BY POWER(备用电源)电门置于OFF位,STANDBYPOWEROFF(备用电源断开)灯会亮,且:()A、交流备用汇流条,静变流机,直流备用汇源条无电B、交流备用汇流条由电瓶通过静交流机供电C、静变流机向1号转换汇流条提供28伏直流电D、以上都不对
考题
A datacenter has exceeded the load on the central uninterruptible power supply (UPS) for the roomand is causing power load problems. Additional power is available, but not using the central UPS. Which of the following is the BEST temporary solution for adding new servers until an upgrade of the central UPS can occur?()A、 Continue plugging into the central UPS, but put the UPS on bypass to avoid load problems.B、 Plug the servers directly into the power that is not on the UPS.C、 Add stand alone UPSs for new servers not wired off the central UPS.D、 Continue plugging into the central UPS because the actual load supported is actually higher than stated.
考题
电源系统是如何向“28V DC HOT BAT BUS”提供电源的?()A、将驾驶舱头顶P5-13面板上的“BAT”电门设置到“BAT”位置B、将驾驶舱头顶P5-5面板上的“STAND BY POWER”电门设置到“AUTO”位置C、将驾驶舱头顶P5-5面板上的“STAND BY POWER”电门设置到“BAT”位置D、电瓶直接与“28VDCHOTBATBUS”相连接
考题
P5板上FLT CONTROL LOW PRESSURE表明()A、仅说明相应液压系统到副翼、升降舵、方向舵相应的液压出现低压B、仅说明相应液压系统到方向舵的油路出现低压。将电门放置在STAND BY RUD位时,当备用方向舵关断活门打开时灯灭C、相应液压系统到副翼、升降舵、方向舵相应的液压出现低压。将电门放置在STAND BY RUD位时,当备用方向舵关断活门打开时灯灭D、相应液压系统到副翼、升降舵、方向舵相应的液压出现低压。将电门放置在STAND BY RUD位时,当备用方向舵关断活门打开时灯亮
考题
下列哪些汇流条无电时会造成STAND BY POWER OFF(备用电源断开)灯亮()A、AC STAND BY BUSB、DC STAND BY BUSC、BATTERY BUSD、以上任意一个
考题
当ECAM上出现绿色的AUDIO 3XFRD信息时,表示().A、音频转换面板上(AUDIO SWITCHING)的转换电门位于CAPT3位置B、音频转换面板上(AUDIO SWITCHING)的转换电门位于F/O3位置C、音频转换面板上(AUDIO SWITCHING)的转换电门位于NORM位置D、A或B
考题
单选题Sailing vessels are stand-on over power-driven vessels except().A
in a crossing situationB
in a meeting situationC
when they are the overtaking vesselD
on the inland waters of the PR China
考题
单选题The most inefficient method of voltage reduction from the stand point of power loss, is a/an ()A
capacitor in series with the loadB
inductor in series with the loadC
capacitor and inductor in series with the loadD
resistor in series with the load
考题
单选题Which one of two crossing power-driven vessels has the right of way in a fog?().A
Both vesselsB
Neither vesselC
The stand-on vesselD
The giving-way vessel
考题
单选题A datacenter has exceeded the load on the central uninterruptible power supply (UPS) for the room and is causing power load problems. Additional power is available, but not using the central UPS. Which of the following is the BEST temporary solution for adding new servers until an upgrade of the central UPS can occur?()A
Continue plugging into the central UPS, but put the UPS on bypass to avoid load problems.B
Plug the servers directly into the power that is not on the UPS.C
Add stand alone UPSs for new servers not wired off the central UPS.D
Continue plugging into the central UPS because the actual load supported is actually higher than stated
考题
单选题() shall be continuously powered and shall have an automatic changeover to a stand by power supply in case of loss of normal power supply.A
Cooling systemB
Alarm systemC
The air conditioning installationD
The mooring equipment
热门标签