If you must pump bilges while a vessel is in port,you should pump only ______.
A.If discharge is led to a shore tank or barge
B.During the hours of darkness
C.On the outgoing tide
D.As much as is necessary
参考答案
更多 “ If you must pump bilges while a vessel is in port,you should pump only ______.A.If discharge is led to a shore tank or bargeB.During the hours of darknessC.On the outgoing tideD.As much as is necessary ” 相关考题
考题
Pump out No. 2 port ballast tank to ______.A.keep vessel afloatingB.refloat vessel listing to starboardC.make vessel all-rightD.bring vessel upright
考题
While on watch in the engine room, you hear a continuous sounding of the general alarm. Which of the following actions should you take?A.Make an entry in the official logbookB.Open the master control valves on the fixed CO2 systemC.Start the fire pump and check discharge pressureD.Secure auxiliary condenser overboard discharge
考题
If it becomes necessary to pump bilges while a vessel is in port, which of the following procedures should be followed?A.Pump only if the discharge is led to a shore tank or bargeB.Pump only during the hours of darknessC.Pump only on the outgoing tideD.Pump only as much as is necessary
考题
If you are the Master of a towing vessel whose only working radar no longer functions,what must you do?A.Notify the Captain of the Port (COTP) if you cannot repair it within 96 hoursB.Notify the Officer in Charge of Marine Inspection (OCMI) if you cannot repair it within 48 hoursC.Moor the vessel until it is repairedD.Anchor the vessel until it is repaired
考题
You are Master of a vessel that is sold in a foreign country after discharge of cargo. What is your responsibility to the crew in regards to return to the United States?A.You must provide air transportation to the nearest port of entry in the United StatesB.You must provide passage to the port of original engagementC.There is no requirement for return to the United States provided the voyage has exceeded 4 weeks durationD.The crew can be employed on another United States vessel,but only if it is returning to the port of original engagement
考题
You start a centrifugal cargo pump to discharge cargo.The pump works for a while and then loses suction.This could be caused by ______.A.The pump running backwardsB.Incomplete primingC.The discharge head being too highD.All of the above
考题
If your radiotelephone fails while underway,______.A.you must visually signal oncoming vesselsB.you must immediately tie up in the nearest port until the radiotelephone is repairedC.you must anchor until the radiotelephone is repairedD.the loss of the radiotelephone must be considered in navigating the vessel
考题
单选题You are Master of a vessel that is sold in a foreign country after discharge of cargo. What is your responsibility to the crew in regards to return to the United States? ()A
You must provide air transportation to the nearest port of entry in the United StatesB
You must provide passage to the port of original engagementC
There is no requirement for return to the United States provided the voyage has exceeded 4 weeks durationD
The crew can be employed on another United States vessel,but only if it is returning to the port of original engagement
考题
单选题You are on a vessel that cannot comply with the spacing requirement for masthead lights.What is required in this situation().A
The vessel must carry only the lights that comply with the rules; the others may be omittedB
The vessel's lights must comply as closely as possible,as determined by her governmentC
The vessel must be altered to permit full compliance with the rulesD
An all-round light should be substituted for the after masthead light and the stern light
考题
单选题You are transporting dangerous cargo on your vessel.You must inspect this cargo().A
DailyB
Daily,at sea onlyC
After encountering rough weatherD
After loading and prior to arrival in port only
考题
单选题If you are the Master of a towing vessel whose only working radar no longer functions,what must you do?()A
Notify the Captain of the Port (COTP) if you cannot repair it within 96 hoursB
Notify the Officer in Charge of Marine Inspection (OCMI) if you cannot repair it within 48 hoursC
Moor the vessel until it is repairedD
Anchor the vessel until it is repaired
考题
单选题You are in charge of a stand-on vessel in a crossing situation.The other vessel is 1.5 miles to port.You believe that risk of collision exists.You should().A
take avoiding action immediately upon determining that risk of collision existsB
immediately sound the danger signalC
take avoiding action only after providing the give-way vessel time to take action ,and determining that her action is not appropriateD
hold course and speed until the point of extremis, and then sound the danger signal, taking whatever action will best avert collision
考题
单选题When loading bulk liquid cargo,what is the FIRST action you should take if a cargo valve jammed open?()A
Trip the pump relief valveB
Order the dock man to shut downC
Call the owner,operator,or terminal supervisorD
Run out the vessel's or terminal's fire hose
考题
单选题If you detect oil in the water around your vessel while discharging fuel, the FIRST thing to do is().A
try to find out where the oil is coming fromB
call the MasterC
have the pump man check the discharge pipingD
shutdown operations
考题
单选题You are about to cross a narrow channel when you see an approaching vessel that can only be navigated safely within the channel.You should().A
cross the channel as you are the stand-on vesselB
cross only if the vessel in the channel is approaching on your port sideC
not cross the channel if you might impede the other vesselD
sound the danger signal
考题
单选题Before attempting to put out a class “C” fire involving an electric-driven centrifugal pump, you should FIRST ().A
insulate your shoesB
ground the fire hoseC
secure its power supplyD
start the fire pump
考题
单选题Pump out No.2 port ballast tank to().A
keep vessel afloatingB
refloat vessel listing to starboardC
make vessel all-rightD
bring vessel upright
考题
单选题While on watch in the engine room, you hear a continuous sounding of the general alarmWhich of the following actions should you take?()A
Make an entry in the official logbookB
Open the master control valves on the fixed CO2 systemC
Start the fire pump and check discharge pressureD
Secure auxiliary condenser overboard discharge
考题
单选题To operate a centrifugal fire pump at reduced capacity, you should ().A
readjust the relief valveB
throttle the suction lineC
throttle the discharge valveD
open the priming line
考题
单选题If it becomes necessary to pump bilges while a vessel is in port, which of the following procedures should be followed?()A
Pump only if the discharge is led to a shore tank or bargeB
Pump only during the hours of darknessC
Pump only on the outgoing tideD
Pump only as much as is necessary
考题
单选题A fire starts on you vessel while refueling. You should first().A
stop the ventilationB
sound the general alarmC
determine the source of the fireD
attempt to extinguish the fire
考题
单选题The terminal indicates to you that they are going to use a booster pump to assist the discharging operation. You start the discharge,and in a few minutes the pressure drops sharply. This could be a result of the().A
booster pump coming on the line and discharging properlyB
booster pump failing to startC
booster pump being lined up in the wrong directionD
ship's pump speeding up
考题
单选题If a bilge pump failed to build up discharge pressure, you should check for ().A
excessive water in the bilgesB
a clogged suction strainerC
oil in the bilgesD
All of the above
考题
单选题You notice oil on the water near your vessel while taking on fuel. You should first().A
stop fuelingB
notify the senior deck officerC
notify the terminal superintendentD
determ ne whether your vessel is the source
考题
单选题When you notice oil on the water near your vessel while taking on fuel, you should FIRST ().A
stop loadingB
notify the senior deck officerC
notify the terminal superintendentD
determine whether your vessel is the source
考题
单选题If a bilge pump is able to develop vacuum, but is unable to sufficiently pump out the bilges, you would check for all of the following EXCEPT ().A
the circuit breakerB
for leaks in the suction pipingC
relief valve is not properly seatedD
the suction strainer
考题
单选题To thoroughly pump out the bilges using a horizontally mounted centrifugal pump, the ().A
pump must always be primedB
volute must impart a radial and rotary motion of the water suction sideC
connection must guide the liquid to the lantern ringsD
stuffing box should not be allowed any water leakage