网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
The brickwork surrounding the firebox of a boiler is known as ______.
A.Refractory
B.The screen wall
C.The water wall
D.Fire plate
参考答案
更多 “ The brickwork surrounding the firebox of a boiler is known as ______.A.RefractoryB.The screen wallC.The water wallD.Fire plate ” 相关考题
考题
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure
考题
The water level in the gauge glass when a boiler is operating is _____ when the boiler is shut down.A.lower thanB.higher thanC.belowD.equal to
考题
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness
考题
A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off
考题
Which statement about the inert gas system is TRUE ________.A.Boiler soot blowers should never be used when the IG system is operatingB.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very lightC.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very lightD.Flue gas with excessive oxygen content is de-oxygenated in the scrubber
考题
单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A
natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB
for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC
the water tube boiler will cost shorter time for steam raisingD
the water tube boiler require lower skill in operating and maintaining
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A
operating the boiler at less than normal water levelB
installing fins on the firesides of water-tubesC
increasing the amount of excess air to the burnersD
treating the boiler water with chemical oxygen scavengers
考题
单选题The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()A
when the boiler has been secured long enough for most solids to settleB
when the boiler has been cooled to ambient temperatureC
only after raising the water level to within 0~5 inch of the high water cutout onlyD
after bypassing the low pressure
考题
单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().A
swellB
shrinkageC
flash offD
lack of water
考题
单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A
salinity is abnormally highB
steam demand is too highC
water level is abnormally lowD
feedwater flow is low
考题
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A
steam demand is highB
salinity is highC
safety valve simmersD
burner flame is extinguished
考题
单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A
excessive purging before lighting offB
insufficient trail for ignition periodC
a faulty transformer in the ignition circuitD
insufficient purging before lighting off
考题
单选题The moisture equilibrium chart can be used to determine the().A
Absolute moisture content of the air surrounding a hygroscopic cargo when moisture equilibrium existsB
Dew point temperature that the air surrounding a hygroscopic commodity will have when in moisture equilibrium with that commodityC
Enthalpy of the air surrounding a hydroscopic cargo which is in moisture equilibrium with the cargoD
Temperature at which moisture equilibrium will occur in a cargo hold containing a hygroscopic cargo
考题
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A
monkeyB
donkeyC
waste heatD
main
考题
单选题A stream of water immediately surrounding a moving vessel’s hull,flowing in the same direction as the vessel is known as().A
directional currentB
forward currentC
propeller currentD
wake current
考题
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A
precipitate silica from solutionB
reduce corrosion in the heating coilC
prevent clogging and erosion in the coilD
maintain zero water hardness
考题
单选题() should be tested and adjusted when the boiler survey is carried out.A
The boiler oil tankB
The steam pipeC
The fire sideD
The safety valves
考题
单选题Foaming in the steam drum may be caused by () in a boiler.A
oxygen in the waterB
poor boiler designC
density too highD
excessive steam demand
考题
单选题When steam is being raised on a boiler, the water level will normally ().A
drop as the boiler warms upB
rise as the boiler warms upC
remain unchanged until the boiler is hot enoughD
rise and fall with the steam demand
考题
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A
caustic embrittlement of the boiler metalB
acidic corrosion of the boiler metalC
hard scale deposits on the boiler tubesD
etching of the heat exchange surfaces
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
考题
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A
10B
7C
4D
1
考题
单选题The brickwork surrounding the firebox of a boiler is known as().A
refractoryB
the screen wallC
the water wallD
fire plate