网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
Foaming in the steam drum may be caused by () in a boiler.
A
oxygen in the water
B
poor boiler design
C
density too high
D
excessive steam demand
参考答案
参考解析
解析:
暂无解析
更多 “单选题Foaming in the steam drum may be caused by () in a boiler.A oxygen in the waterB poor boiler designC density too highD excessive steam demand” 相关考题
考题
Poor posture of moving and handling may be caused by . ()
A. painB. personal habitsC. muscle imbalanceD. degenerative process
考题
The water level showing in a boiler water gauge glass is usually ( ) duringworking.A.higher than the actual drum water levelB.equal to the actual drum water levelC.increasing due to steam condensation in the glassD.lower than actual drum wafer level
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
汉译英:“塑料桶、麻袋、木箱”( )。
A. plastic drum; gunny bag; wooden case B. wooden case; plastic drum; gunny bag
C. wooden case; gunny bag; plastic drum D. plastic drum; wooden case; gunny bag
考题
A system administrator thinks that a filesystem may be full and that is what caused the machine to crash. Which command will show the administrator if they are correct?()A、 du B、 df C、 fsck D、 ncheck
考题
单选题In regions where ice conditions prevail in the winter,().A
the lantern panes of unattended lights may not become covered with ice or snowB
the lantern panes of unattended lights may become covered with ice or snowC
ice or snow is likely caused coloredD
the white lights are likely caused to appear colored
考题
单选题What is NOT a function of the steam drum of a marine water-tube boiler().A
Receives saturated steam from the generating tubesB
Serves as a reservoir of boiler feed waterC
Holds internal fittings for separation of moisture from steamD
Collects steam exhausted from the turbines
考题
单选题When a sudden increase in steam demand occurs from the boiler, the water level in the drum at the higher pressure will()A
rise quicklyB
rise slowlyC
drop quicklyD
drop slowly
考题
单选题A water pump can not supply water after startingIt may be caused by ().A
closed discharge valveB
broken pipe lineC
worn shaftD
both A and B
考题
单选题A gypsy or gypsyhead is a().A
punt used for painting over the sideB
small, reciprocating steam engineC
spool-shaped drum fitted on a winchD
swinging derrick
考题
单选题The load between two steam-driven alternators operating in parallel may be adjusted by varying ()A
the speed of the alternatorsB
the field strength of the machinesC
the power factor of the alternatorsD
steam supply to the prime movers
考题
单选题Waterside scale in a fire-tube boiler may cause ().A
increased heat transferB
fireside erosionC
high steam demandD
overheated tubes
考题
单选题When a sudden increase in steam demand comes to normal, the drum pressure will and water level in the drum will().A
rise, rise alsoB
rise, dropC
drop, riseD
drop, drop also
考题
单选题In a refrigeration system, foaming of the crankcase oil may cause the ().A
expansion valve to overfeedB
compressor to knockC
water regulating valve to failD
crankcase drains to plug
考题
单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.A
main stem stop valveB
auxiliary steam stop valveC
feed check or control valveD
blow down valve
考题
单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().A
swellB
shrinkageC
flash offD
lack of water
考题
单选题Electrical failures in motors are caused by the breakdown of insulation, which may be caused by ()A
penetration of moistureB
accumulation of dirtC
overheatingD
All of the above
考题
单选题Blow-off of the relief valves of the engines cylinders may be caused by ().A
too low leadB
water in fuelC
too tight springD
leakage
考题
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A
refrigerant boiling out of solution from the lube oilB
liquid refrigerant flooding the compressor and systemC
lube oil viscosity being reduced by refrigerant dilutionD
compressor suction pressure suddenly increasing
考题
单选题The reciprocating pump can’t draw water from a tank may be caused by ().A
leaky pipeB
opened inlet valveC
too much water in tankD
None of the above
考题
单选题() may be fitted for operating the derrick topping lift (the wire which adjusts the derrick height).A
A capstanB
A holdC
A warp endD
A mooring drum
考题
单选题I must hold()for any damage which may result from the accidents you have caused.A
your responsibleB
you responsibleC
you are responsibleD
your are responsible
考题
单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A
carbon deposits on the flame scannerB
high fuel oil temperatureC
low fuel oil viscosityD
high steam pressure
考题
单选题External and internal leakage in hydraulic systems may be caused by ().A
unusual vibrationB
excessive worn partsC
abnormal pressureD
any of the above
考题
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A
ensure feed water flow into the boilerB
keep the steam drum pressure highC
prevent water hammer in the feed lineD
help the feed water flash to steam
考题
单选题The water level showing in a boiler water gauge glass is usually () during working.A
higher than the actual drum water levelB
equal to the actual drum water levelC
increasing due to steam condensation in the glassD
lower than actual drum water level
考题
单选题(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.A
An economizerB
An attemperatorC
A water dramD
A down-comer tube