Which of the problems listed could cause erosion of the expansion valve disks and seats?
A.Overcharging the system with refrigerant
B.Faulty compressor suction valve
C.Failure of the high pressure cutout
D.Flash gas formed in the liquid line
参考答案
更多 “ Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line ” 相关考题
考题
Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve
考题
The main propulsion diesel engine jacket water temperature rises above normal, with the raw sea suction and the expansion tank water level being normal. Which of the following problems is most likely the cause?A.Faulty thermostatic bypass valveB.Eroded zinc pencils in the heat exchangerC.Steam formation in the expansion tankD.Excessive leakage from jacket water pump seals
考题
Which of the listed problems could produce a high absolute pressure within a flash type evaporator?A.production of high salinity distillateB.seawater feed temperature below 165℃C.a leak in the first stage demisterD.a cracked distillate pump vent line
考题
单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A
Proper refrigerant chargeB
Faulty expansion valveC
Insufficient refrigerantD
Solenoid valve stuck open
考题
单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()A
cold fuel oilB
low fuel oil pressureC
low atomizing steam pressureD
water in the fuel oil
考题
单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()A
Worn intake valve guidesB
Pitted pre-combustion chambersC
Loose valve tappetsD
High exhaust back pressure
考题
单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A
Shortage of refrigerant oilB
Slight shortage of refrigerantC
Excessive condenser cooling water flowD
Faulty expansion valve
考题
单选题Which of the listed problems can be a cause of low compression pressure in a diesel engine?()A
clogged air filterB
compression strokeC
burned exhaust valvesD
all of the above
考题
单选题Which of the valves listed is NOT considered to be a hydraulic system directional control valve?()A
Spring-centered valveB
Unloading valveC
Three-position valveD
Two-position valve
考题
单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A
Closing of the solenoid valveB
Closing of the expansion valveC
An increase in the suction pressureD
Decreasing the suction pressure
考题
单选题Which of the listed problems could produce a high absolute pressure within a flash type evaporator?()A
Production of high salinity distillateB
Seawater feed temperature below 165℃C
A leak in the first stage demisterD
A cracked distillate pump vent line
考题
单选题If the jacket water temperature of an operating diesel engine suddenly rises above normal, the cause can be attributed to ().A
an overfilled expansion tankB
excess chromate treatment of the jacket waterC
a clogged raw water sea suctionD
cavitation erosion of the heat exchanger tubes
考题
单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().A
openB
closeC
remain in its positionD
flood the evaporator with refrigerant
考题
单选题Which of the problems listed represents the major difficulty encountered with thermal expansion valve operation?()A
Lube oil passing through the systemB
Moisture or foreign matter collecting at the valve seat and orificeC
Variable spring tension caused by the changing temperatureD
Frost on the liquid line
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题Which of the conditions listed could cause the cylinder relief valves on a large, low-speed, propulsion diesel engine to lift?()A
Plugged injector nozzlesB
Excessive fuel injectionC
Very late injection timingD
Incorrect crankshaft clearance
考题
单选题Which of the following problems could cause air to blow out through the inlet air filter of a running compressor?()A
Excessive compression in the cylinderB
A broken intake valveC
A dirty inlet filter elementD
An improperly adjusted discharge valve
考题
单选题Which of the following would not cause high suction pressure?()A
insufficient refrigerationB
leaky suction valvesC
expansion valve stuck openD
suction valve not adjusted properly
考题
单选题Moisture in a refrigeration system can cause ().A
freezing the expansion valve closedB
corrosion of system pipingC
improper temperature regulationD
all of the above
考题
单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().A
return to a neutral positionB
flood the evaporatorC
openD
close
考题
单选题Which of the listed statements is correct concerning refrigeration systems?()A
Dehydrators must be used continuously in a refrigeration systemB
A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC
A thermostatic expansion valve is used to control refrigerated space temperatureD
The liquid receiver functions to collect and remove non- condensable gases
考题
单选题If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?()A
The wearing rings are excessively wornB
The suction strainer is cloggedC
The discharge valve is cloggedD
The shaft is worn
考题
单选题Which of the listed design features is found in an exhaust valve and NOT in an intake valve?()A
Hard alloy steel constructionB
Beveled edges on the valve headC
Low alloy steel constructionD
Poppet type design
考题
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A
The condenser and the expansion valveB
The king valve and the solenoid valveC
The compressor and the expansion valveD
The condenser and the solenoid valve
考题
单选题Which of the following problems would be the probable cause for the faulty operation of a reciprocating air compressor suction valve?()A
Carbon build up in the piston ring beltB
Faulty operation of a cylinder un-loaderC
Compressor operation in an area of high relative humidityD
Lifting of intercooler rebel valve
考题
单选题A pressure drop in the liquid line of a refrigeration system may cause()A
the solenoid valve to seizeB
the compressor to huntC
flash gas to form in the liquid lineD
the expansion valve to freeze open
考题
单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A
Thermal expansion valve frozen openB
Suction gas heat exchanger bypassedC
Condenser clogged or fouledD
High pressure cutout switch inoperative