网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

Which of the problems listed could cause erosion of the expansion valve disks and seats?

A.Overcharging the system with refrigerant

B.Faulty compressor suction valve

C.Failure of the high pressure cutout

D.Flash gas formed in the liquid line


参考答案

更多 “ Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line ” 相关考题
考题 Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

考题 The main propulsion diesel engine jacket water temperature rises above normal, with the raw sea suction and the expansion tank water level being normal. Which of the following problems is most likely the cause?A.Faulty thermostatic bypass valveB.Eroded zinc pencils in the heat exchangerC.Steam formation in the expansion tankD.Excessive leakage from jacket water pump seals

考题 Which of the listed problems could produce a high absolute pressure within a flash type evaporator?A.production of high salinity distillateB.seawater feed temperature below 165℃C.a leak in the first stage demisterD.a cracked distillate pump vent line

考题 单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A Proper refrigerant chargeB Faulty expansion valveC Insufficient refrigerantD Solenoid valve stuck open

考题 单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()A cold fuel oilB low fuel oil pressureC low atomizing steam pressureD water in the fuel oil

考题 单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()A Worn intake valve guidesB Pitted pre-combustion chambersC Loose valve tappetsD High exhaust back pressure

考题 单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A Shortage of refrigerant oilB Slight shortage of refrigerantC Excessive condenser cooling water flowD Faulty expansion valve

考题 单选题Which of the listed problems can be a cause of low compression pressure in a diesel engine?()A clogged air filterB compression strokeC burned exhaust valvesD all of the above

考题 单选题Which of the valves listed is NOT considered to be a hydraulic system directional control valve?()A Spring-centered valveB Unloading valveC Three-position valveD Two-position valve

考题 单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A Closing of the solenoid valveB Closing of the expansion valveC An increase in the suction pressureD Decreasing the suction pressure

考题 单选题Which of the listed problems could produce a high absolute pressure within a flash type evaporator?()A Production of high salinity distillateB Seawater feed temperature below 165℃C A leak in the first stage demisterD A cracked distillate pump vent line

考题 单选题If the jacket water temperature of an operating diesel engine suddenly rises above normal, the cause can be attributed to ().A an overfilled expansion tankB excess chromate treatment of the jacket waterC a clogged raw water sea suctionD cavitation erosion of the heat exchanger tubes

考题 单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().A openB closeC remain in its positionD flood the evaporator with refrigerant

考题 单选题Which of the problems listed represents the major difficulty encountered with thermal expansion valve operation?()A Lube oil passing through the systemB Moisture or foreign matter collecting at the valve seat and orificeC Variable spring tension caused by the changing temperatureD Frost on the liquid line

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题Which of the conditions listed could cause the cylinder relief valves on a large, low-speed, propulsion diesel engine to lift?()A Plugged injector nozzlesB Excessive fuel injectionC Very late injection timingD Incorrect crankshaft clearance

考题 单选题Which of the following problems could cause air to blow out through the inlet air filter of a running compressor?()A Excessive compression in the cylinderB A broken intake valveC A dirty inlet filter elementD An improperly adjusted discharge valve

考题 单选题Which of the following would not cause high suction pressure?()A insufficient refrigerationB leaky suction valvesC expansion valve stuck openD suction valve not adjusted properly

考题 单选题Moisture in a refrigeration system can cause ().A freezing the expansion valve closedB corrosion of system pipingC improper temperature regulationD all of the above

考题 单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().A return to a neutral positionB flood the evaporatorC openD close

考题 单选题Which of the listed statements is correct concerning refrigeration systems?()A Dehydrators must be used continuously in a refrigeration systemB A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC A thermostatic expansion valve is used to control refrigerated space temperatureD The liquid receiver functions to collect and remove non- condensable gases

考题 单选题If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?()A The wearing rings are excessively wornB The suction strainer is cloggedC The discharge valve is cloggedD The shaft is worn

考题 单选题Which of the listed design features is found in an exhaust valve and NOT in an intake valve?()A Hard alloy steel constructionB Beveled edges on the valve headC Low alloy steel constructionD Poppet type design

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve

考题 单选题Which of the following problems would be the probable cause for the faulty operation of a reciprocating air compressor suction valve?()A Carbon build up in the piston ring beltB Faulty operation of a cylinder un-loaderC Compressor operation in an area of high relative humidityD Lifting of intercooler rebel valve

考题 单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open

考题 单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A Thermal expansion valve frozen openB Suction gas heat exchanger bypassedC Condenser clogged or fouledD High pressure cutout switch inoperative