A pressure drop in the liquid line of a refrigeration system may cause()
A

the solenoid valve to seize

B

the compressor to hunt

C

flash gas to form in the liquid line

D

the expansion valve to freeze open


参考答案

参考解析
解析: 暂无解析
更多 “单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open” 相关考题
考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid line If excess moisture is present in the system, the indicator willA.activate the driersB.change colorC.secure the compressorD.add a predetermined amount of liquid drier

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid lineIf excess moisture is present in the system, the indicator will ()A activate the driersB change colorC secure the compressorD add a predetermined amount of liquid drier

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题A pressure drop through the refrigerant liquid line may cause ().A solenoid valve to seizeB compressor to huntC formation of flash gas in the liquid lineD expansion valve to freeze open

考题 单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().A compressorB condenserC throttle valveD evaporator

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().A cause a loss of the liquid sealB create a vapor lock in the liquid receiverC collect in the condenserD cause foaming of the oil in the crankcase

考题 单选题The static suction head of is the ()A distance of the suction liquid level above the line of the pumpB distance the suction liquid level is below the center line of the pumpC force necessary to overcome frictional losses in the pump and pipingD amount in inches of mercury the total suction head is below atmospheric pressure

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题The receiver used in a refrigeration system()A stores liquid refrigerantB collects non-condensable gasesC allows refrigerant sub-coolingD prevents compressor surging

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion