单选题
The load rating of an AC generator is determined by the()
A
internal heat it can withstand
B
load it can carry continuously
C
load it is capable of supplying
D
overload it can carry for a specified time only
参考答案
参考解析
解析:
暂无解析
更多 “单选题The load rating of an AC generator is determined by the()A internal heat it can withstandB load it can carry continuouslyC load it is capable of supplyingD overload it can carry for a specified time only” 相关考题
考题
The output voltage of a 440 volt, 60 hertz, AC generator is controlled by theA.prime mover speedB.exciter output voltageC.load on the alternatorD.number of poles
考题
The frequency of an AC generator is controlled by theA.rheostatB.governorC.exciterD.capacitor
考题
The division of kilowatt load between two paralleled alternators is determined by theA.amount of field excitation of the leading machineB.load-speed characteristics of the governorsC.amount of field excitation to the lagging machineD.type of alternator
考题
The frequency of an AC generator is controlled by the ___.A.rheostatB.governorC.exciterD.capacitor
考题
The power factor of an AC generator operating singularly is determined by the_______ .A.connected loadB.prime mover speedC.field excitationD.generator's rated voltage
考题
单选题The purpose of DC generator brushes is to ().A
neutralize armature reactionB
conduct electric current to an outside circuitC
convert DC current to AC currentD
provide excitation to a DC generator
考题
单选题A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an ()A
rotorB
statorC
exciterD
armature
考题
单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().A
droopB
dropC
dipD
regulation
考题
单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.A
whenB
so asC
such thatD
though
考题
单选题The power factor of an AC generator operating singularly is determined by the ()A
connected loadB
prime mover speedC
field excitationD
generators rated voltage
考题
单选题When securing an AC generator, you should FIRST ().A
open the generator circuit breakerB
switch the voltage regulator to “manual”C
decrease the field excitation to minimumD
reduce the load on the unit
考题
单选题The frequency of an AC generator is controlled by the ()A
rheostatB
governorC
exciterD
capacitor
考题
单选题To increase the frequency of an operating AC generator, you should ()A
increase the field excitationB
decrease the field excitationC
increase the number of magnetic polesD
increase the speed of the prime mover
考题
单选题Most often () is attached to the engine-propeller shaft for efficient electric power generation.A
a variable-speed AC generatorB
a fixed-speed AC generatorC
an air blowerD
a DC generator
考题
单选题An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()A
weekB
2 weeksC
monthD
3 months
考题
单选题The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().A
load limit settingsB
idle speed settingsC
speed limit settingsD
speed droop settings
考题
单选题The frequency of an AC generator is adjusted by means of the ()A
main alternator field rheostatB
exciter field rheostatC
prime mover governor controlD
equalizing reactor
考题
单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().A
is smallB
may be neglectedC
is usefulD
is considerable
考题
单选题The purpose of the commutator and brushes on a DC generator is to()A
change AC to DCcurrentB
change DC to AC currentC
neutralize a armature reactionD
carry current to the outside circuit
考题
单选题The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the ().A
prime mover speedB
exciter output voltageC
load on the alternatorD
number of poles
考题
单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()A
an incorrect diesel generator governor speed droop adjustmentB
a faulty reverse power relay within the main circuit breaker assemblyC
unsynchronized isochronous load distribution adjustmentsD
a different speed setting on each unit
考题
单选题Which of the following statements is correct regarding a turbocharged four-stroke/cycle diesel generator?()A
At zero load the intake manifold pressure is greater than the exhaust manifold pressureB
At full load the intake manifold pressure and exhaust manifold pressure are equalC
At full load the intake manifold pressure is less than the exhaust manifold pressureD
At full load the intake manifold pressure is greater than the exhaust manifold pressure
考题
单选题Which of the following should be the FIRST step in removing a generator from parallel operation?()A
Trip the generator off the switchboardB
Turn off all electrical equipmentC
Remove the load from the off going generatorD
Increase the cycles of the generator staying on the line
考题
单选题A vessel is equipped with two ships service generatorsGenerator #1 is rated at 900kw and generator #2 is rated at 600kw.During parallel operation, with a hotel load of 1000kw, what should be the kw load on generator #2 ().A
100kwB
400kwC
500kwD
600kw
考题
单选题A constant output voltage from an AC generator is maintained by the ().A
prime mover governorB
exciter generatorC
voltage regulatorD
reverse power relay