The sensing line for the low pressure cutout switch to a refrigeration system is located ().
A
in the chill box
B
before the receiver
C
on the suction side of the compressor
D
on the discharge side of the compressor
参考答案
参考解析
解析:
暂无解析
更多 “单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor” 相关考题
考题
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure
考题
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
考题
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
考题
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
考题
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A
pressurestatB
high pressure cutoutC
solenoid valveD
low pressure cutout switch
考题
单选题The refrigeration system low pressure cutout switch is actuated by ().A
an electric system managerB
a sensing bulb at the tail coil of the evaporatorC
pressure changes in the suction lineD
failure of the king solenoid valve
考题
单选题The device used for low-pressure control and high-pressure cutout on a compressor is called a()A
cutoutB
pressure controllerC
controller switchD
cutout switch
考题
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A
the compressor suction pressure is not too highB
all air is purged from the pump and charging fittingsC
the high pressure cutout switch is held open to prevent accidental startingD
the condenser is completely shutdown first
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题Two well-developed high pressure areas may be separated by a().A
Hill of low pressureB
Trough of low pressureC
Valley of low pressureD
Ridge of low pressure
考题
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A
system was overcharged with refrigerantB
high pressure switch was improperly adjustedC
expansion valve strainers were fouledD
suction valves were leaking slightly
考题
单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A
system was overcharged with refrigerantB
system was low on refrigerantC
suction valves were leaking slightlyD
relief valve was leaking slightly
考题
单选题If the compressor runs continually, the cause might be the()A
high-pressure cutout switch is jammed openB
low-pressure switch is jammed shutC
thermal bulb is not operating properlyD
scale trap is clogged
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()A
when the boiler has been secured long enough for most solids to settleB
when the boiler has been cooled to ambient temperatureC
only after raising the water level to within 0~5 inch of the high water cutout onlyD
after bypassing the low pressure
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题If the head pressure is too high,()A
the relief valve should open before the high-pressure cutoutB
the relief valve should open and let excess refrigerant go to receiverC
the high-pressure cutout switch should operate before the relief valve opensD
close in on the suction valve
考题
单选题The direction of the surface wind is().A
directly from high pressure toward low pressureB
directly from low pressure toward high pressureC
from high pressure toward low pressure deflected by the earth's rotationD
from low pressure toward high pressure deflected by the earth's rotation
考题
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A
system is overcharged with refrigerantB
system is low on refrigerantC
discharge valves are leaking excessivelyD
discharge valves are leaking slightly
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题Diesel engine automated control systems may utilize sensing devices of dual function, with sensing ranges providing both alarm and engine shut down capability.Which of the key points would only require an alarm sensor?()A
Lube oil pressure and temperatureB
jacket water pressure and temperatureC
Engine over-speedD
Lube oil sump level
考题
单选题If a compressor runs continuously, the cause might be a()A
defective thermal bulbB
clogged scale trapC
stuck high-pressure switchD
stuck low-pressure switch
考题
单选题The purpose of the low pressure cut-out switch is to ().A
maintain liquid refrigerant at the suction of the compressorB
maintain a preset suction pressure to the compressorC
start and stop the compressor at preset operating pressuresD
operate at minimum efficiency
考题
单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A
Thermal expansion valve frozen openB
Suction gas heat exchanger bypassedC
Condenser clogged or fouledD
High pressure cutout switch inoperative