The 12-foot low-velocity fog applicator().
A

has a spray pattern 12 feet in diameter

B

can be used in conjunction with both 1-1/2 inch and 2-1/2 inch all-purpose nozzles

C

has a 90°bend at its discharge end

D

has a screw thread end which connects to the all-purpose nozzle


参考答案

参考解析
解析: 暂无解析
更多 “单选题The 12-foot low-velocity fog applicator().A has a spray pattern 12 feet in diameterB can be used in conjunction with both 1-1/2 inch and 2-1/2 inch all-purpose nozzlesC has a 90°bend at its discharge endD has a screw thread end which connects to the all-purpose nozzle” 相关考题
考题 The()headlights of the cars could be seen through the fog. A、glowingB、gleaming

考题 Dense fog comes with bad visibility, fog signal bell must be kept ________at regulation intervalsA.to goB.goingC.goesD.go

考题 A mobile offshore drilling unit under tow is approaching a fog bank. When should fog signals be started?A.When the towing vessel enters the fogB.When the drilling rig enters the fogC.When the towing vessel can no longer be seen from the rigD.Immediately

考题 The difference in water spray pattern between the high-velocity tip and low-velocity applicator used with the all-purpose nozzle is due to ______.A.a difference in water pressureB.the method of breaking up the water streamC.the length of the applicatorD.All of the above

考题 If a firefighting situation calls for low-velocity fog you would ______.A.order the engine room to reduce pressure on the fire pumpB.put the lever on an all-purpose fire nozzle all the way forwardC.attach a low-velocity fog applicator with the nozzle shut downD.put the lever on an all-purpose fire nozzle all the way back

考题 Firefighting foam is only effective when the foam _____.A.penetrates to the bottom of the fireB.is kept saturated with low-velocity water fogC.mixes with the burning fuel oilD.completely covers the top of the burning liquid

考题 If not attached to the nozzle, each low-velocity spray applicator on a vessel must be stowed__________.A.in a protected area on the main deckB.inside a machinery space near the entranceC.next to the fire hydrant to which the fire hose is attachedD.on a rack inside the quarters near the entrance

考题 The personnel department requires that all ( )be interviewed at least three times before a hiring decision is made. A. applications B. applicants C. appliances D. applicator

考题 什么是“照相灰雾(Photo graphic fog)”和“曝光灰雾(exposure fog)”?

考题 雾号()A、beaconB、fog beaconC、foghornD、siren

考题 单选题If a firefighting situation calls for low-velocity fog you would().A order the engine room to reduce pressure on the fire pumpB put the lever on an all-purpose fire nozzle all the way forwardC attach a low-velocity fog applicator with the nozzle shut downD put the lever on an all-purpose fire nozzle all the way back

考题 单选题A mobile offshore drilling unit under tow is approaching a fog bank. When should fog signals be started? ()A When the towing vessel enters the fogB When the drilling rig enters the fogC When the towing vessel can no longer be seen from the rigD Immediately

考题 单选题The ship should reduce speed in the thick fog because of().A the poor visibilityB the fog signalsC the fast speedD the good sight

考题 单选题What is the use of the books of Admiralty List of Lights and Fog Signals? Their use is to ().A Mention signal stations and ice,storm,traffic and port signalsB Give the international numbers of lightsC Give the correction of the lights and fog signalsD Give the information on the lights and fog signals

考题 单选题The fog most commonly encountered at sea is called().A conduction fogB radiation fogC frontal fogD advection fog

考题 单选题Radiation fog is more commonly encountered in().A springB later winterC autumnD end of summer

考题 单选题The all-purpose nozzle will produce a fog spray when you().A pull the nozzle handle all the way back toward the operatorB pull the nozzle handle back to a position where the handle is perpendicular to the plane of the nozzleC push the nozzle handle forward as far as it will goD insert a fog applicator between the fire hose and nozzle

考题 单选题High-velocity fog().A is a finer,more diffuse water spray than low-velocity fogB requires that the water pressure be no greater than 60 psiC produces an effective fog pattern no more than 6 feet beyond the nozzleD extinguishes a fire by absorbing heat and reducing the supply of oxygen

考题 单选题A tug is towing three manned barges in line in fog. The first vessel of the tow should sound ().A no fog signalB one short blastC one prolonged and three short blastsD one prolonged,one short,and one prolonged blast

考题 单选题An instrument useful in predicting fog is the().A sling psychrometerB microbarographC anemometerD aneroid barometer

考题 单选题Which kind of fog is also named as ground fog?()A AdvectionB Radiation fogC frontal fogD Steam fog

考题 单选题()gives listings of all lighthouses,lightships,lit floating marks(over 8m in height),fog signals and lights of navigational significance.A Ocean Passages for the WorldB Admiralty List of Radio SignalsC IALA Maritime Buoyage SystemD Admiralty List of Lights and Fog Signals

考题 单选题The difference in water spray pattern between the high-velocity tip and low-velocity applicator used with the all-purpose nozzle is due to().A a difference in water pressureB the method of breaking up the water streamC the length of the applicatorD All of the above

考题 单选题If a fire occurs in the boiler room as a result of a leaking fuel line, you should FIRST ().A notify the engineer on watchB isolate and secure the pipingC throw sand on the fireD extinguish the fire using a combination nozzle with applicator

考题 单选题The spray of water in low-velocity fog will have().A greater range than high-velocity fogB lesser range than high-velocity fogC about the same range as high-velocity fogD greater range than a solid stream

考题 单选题A combination or all-purpose nozzle produces().A low-velocity fog onlyB a solid stream onlyC a solid stream and foamD a solid stream and fog

考题 单选题Firefighting foam is only effective when the foam().A penetrates to the bottom of the fireB is kept saturated with low-velocity water fogC mixes with the burning fuel oilD completely covers the top of the burning liquid