A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().
A

condition of the expansion valve

B

moisture in the system

C

condition of the compressor suction valves

D

condenser temperature


参考答案

参考解析
解析: 暂无解析
更多 “单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().A condition of the expansion valveB moisture in the systemC condition of the compressor suction valvesD condenser temperature” 相关考题
考题 On the balance sheet, assets and liabilities are classified as either (61) or long-term to indicate their relative liquidity. Liquidity is a (62) of how quickly an item may be converted to cash. Therefore, (63) is the most liquid asset. Accounts receivable are a (64) liquid asset because the business expects to collect the amount in cash in the near future. (65) are less liquid than accounts receivable, and furniture and buildings are even less so.(46)A.short-termB.currentC.circulatingD.futures

考题 underline 的意思是:draw a line under to give emphasis or indicate special type() 此题为判断题(对,错)。

考题 Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid line If excess moisture is present in the system, the indicator willA.activate the driersB.change colorC.secure the compressorD.add a predetermined amount of liquid drier

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 Areas enclosed by a long and short dashed magenta line indicate ______.A.cable areasB.dumping groundsC.fish trap areasD.precautionary areas

考题 The height of eye correction is smaller than geometrical dip because of ______.A.the angle between the horizontal and the line of sight to the visible horizonB.index errorC.parallaxD.terrestrial refraction

考题 At sea you sight two red lights. This would indicate ______.A.A vessel engaged in laying cableB.A vessel not under commandC.A vessel launching and recovering aircraftD.All of the above

考题 智真主机TH1000的音频接口类型包括()A、MIC输入B、Line InC、Line OutD、AUX

考题 视线关系(Line of Sight,LoS)

考题 单选题Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid lineIf excess moisture is present in the system, the indicator will ()A activate the driersB change colorC secure the compressorD add a predetermined amount of liquid drier

考题 单选题The device, which is installed in the compressor suction line to prevent liquid from entering the compressor when hot gas defrosting, is called a()A re-evaporatorB receiverC dehydratorD solenoid

考题 单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A Proper refrigerant chargeB Faulty expansion valveC Insufficient refrigerantD Solenoid valve stuck open

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题Before liquid can flow into a pump, the air in the suction line must be () sufficiently to cause the liquid to flow into the suction chamber.A filledB evacuatedC compressedD charged

考题 单选题A star is observed at lower transit. The line of position derived from this sight is().A on the prime verticalB a latitude lineC a longitude lineD of no special significance

考题 单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A too much refrigerant in the systemB oil entrained in the refrigerantC less than a full charge of refrigerant in the systemD ice crystals forming in the refrigerant

考题 单选题Areas enclosed by a long and short dashed magenta line indicate ().A cable areasB dumping groundsC fish trap areasD precautionary areas

考题 单选题Air entering an air-cooled refrigeration system is indicated by ().A frosting of the liquid lineB higher than normal head pressureC a clear sight glassD abnormally cold reefer boxes

考题 单选题A pressure drop through the refrigerant liquid line may cause ().A solenoid valve to seizeB compressor to huntC formation of flash gas in the liquid lineD expansion valve to freeze open

考题 单选题The height of eye correction is smaller than geometrical dip because of ().A the angle between the horizontal and the line of sight to the visible horizonB index errorC parallaxD terrestrial refraction

考题 单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A the compressor short cycling on high pressure cut out switchB high suction pressureC high head pressureD bubbles in the sight glass

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题The static suction head of is the ()A distance of the suction liquid level above the line of the pumpB distance the suction liquid level is below the center line of the pumpC force necessary to overcome frictional losses in the pump and pipingD amount in inches of mercury the total suction head is below atmospheric pressure

考题 单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open

考题 单选题A marine sextant has the index arm set at zero and the reflected image of the horizon forms a continuous line with the actual image. When the sextant is rotated about the line of sight the images separate. The sextant has().A error of perpendicularityB side errorC prismatic errorD centering error

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion