网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().
A

running at the same speed

B

grounded

C

of the same polarity

D

in phase


参考答案

参考解析
解析: 暂无解析
更多 “单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().A running at the same speedB groundedC of the same polarityD in phase” 相关考题
考题 How many generators does the shuttle carry?A.One.B.Two.C.Three.D.Four.

考题 ( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

考题 You are attempting to parallel two AC.generators, and the synchroscope pointer revolving in the fast direction.This indicates that the frequency of the incoming machine is A.higher than the bus equencyB.lower than the bus equencyC.the same as the bus frequency but out of phase with itD.same as the bus frequency and the circuit breaker may be closed at

考题 Where could you monitor the correct instant for synchronizing without aid of synchroscope or synchronizing lamp? A.Distribution boardB.Section boardC.Emergency switchboardD.Main switchboard

考题 You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine isA.higher than the bus frequencyB.lower than the bus frequencyC.file same as file bus frequency but out of phase with itD.the same as the bus frequency, and the circuit breaker may be closed at nay pointer position

考题 While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase

考题 IV测试仪氙灯灯管两端LAMP+和LAMP-之间的电压为()。A、AC700VB、DC700VC、AC1000VD、DC1000V

考题 While planning the logical volume design of a new install, Companycom considered using a striped logical volume for performance. They want to be able to extend the logical volume in the future. Which of the following actions will provide this capability?()A、Add additional logical volumes two at a timeB、Add additional physical volumes two at a timeC、Create a columned striped logical volume using -C option of mklvD、Create an extendable striped logical volume using -E option of mklv

考题 单选题A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet the customer requirements while reducing single points of failure?()A AB BC CD D

考题 单选题Voltage generated by most AC generators is fed from the machine to the bus by means of().A brushes on a commutatorB brushes on slip ringsC slip rings on a commutatorD direct connections from the stator

考题 单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().A voltage regulatorsB field rheostatsC reverse power relaysD prime mover governors

考题 单选题Which is a function of the voltage regulators used with AC generators?()A To cut out generators when they are no longer requiredB To cut in additional generators automatically as requiredC To divide the KW load equally between generators operating in parallelD To divide reactive current between generators operating in parallel

考题 单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()A an electrical interlock systemB an automatic paralleling trip switchC the synchronizing oscilloscopeD the reverse current relay

考题 单选题Electric generators can be protected against overload().A With switchesB With a governor on the engineC With fuses or circuit breakersD By using heavy wire

考题 单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().A running at the same speedB groundedC of the same polarityD in phase

考题 单选题An alternator switchboard has a synchroscope and synchronizing lamps, if the synchroscope is broken, which of the steps listed is the most essential before an alternator can be paralleled with the bus ()A The breaker should be closed when one synchronizing lamp is dark and the other is brightB The breaker should be closed when both synchronizing lamps are brightC The frequency meter should be used to determine that the incoming alternator frequency is slightly higher than the busD A portable phase sequence indicator must be used to verify the information from the lamps

考题 单选题Equal power factors on paralleled AC generators are maintained by an automatic ().A voltage regulatorB reverse power relayC reverse current relayD governor control switch

考题 单选题When two AC generators are being paralleled, the breaker should be closed with the synchroscope pointer mating in the ()A slow direction, just before the 12 o'clock positionB fast direction, just after the 12 o'clock positionC fast direction, just before the 12 o'clock positionD slow direction, just after the 12 o'clock position

考题 单选题The operation of paralleling two alternators requires the voltages to be ()and also in phase.A zeroB eliminatedC differentD equal

考题 单选题When paralleled, AC generators must have the same ()A frequencyB number of phasesC phase rotationD All of the above

考题 单选题When two DC generators operate in parallel, they are protected against motorizing by()A blow out coilsB governor relayC under voltage tripsD reverse current trips

考题 单选题If two AC generators are to be operated in parallel, the load is distributed evenly by()A means of rheostat the governor settingsB a balance coil excitationC adjusting the governor settingsD changing excitation

考题 单选题You are attempting to parallel two AC generators, and the syncope pointer is revolving in the fast directionThis indicates that the frequency of the incoming machine is ().A higher than the bus frequencyB lower than the bus frequencyC the same as the bus frequency but out of phase with itD the same as the bus frequency and the circuit breaker may be closed at any pointer position

考题 单选题If two AC generators are operated in parallel, the load is distributed evenly by()A a rheostatB a balancing coilC changing field excitationD adjusting the governor settings

考题 问答题Which lamp is the brightest?  Lamp A is less brighter than Lamp B;  Lamp B is brighter than Lamp C;  Lamp C is as bright as Lamp D;  Lamp B is brighter than Lamp D;  Lamp D is brighter than Lamp A.

考题 单选题If two A.C.generators are to be operated in parallel, the load is distributed evenly by()A means of rheostat the governor settingsB a balance coil excitationC adjusting the governor settingsD changing excitation

考题 单选题Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine ()A slightly less than the line frequencyB the same as the line frequencyC slightly greater than the line frequencyD All of the above

考题 单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()A slightly less than the oncoming generator frequencyB the same as the bus frequencyC slightly greater than the bus frequencyD the same as the bus voltage