A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()
A

2

B

4

C

6

D

8


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A 2B 4C 6D 8” 相关考题
考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation.What multipathing driver is required to build a redundant solution?()A.RDACB.MPIOC.SSPCD.SDDPCM

考题 A customer is currently using a Windows file server to share NFS storage (9 TB) to theirapplication server, and a small SAN to supply block I/O to their database servers (5 TB). As theircurrent hardware is aging they are looking for a new best of breed technology to combine file andblock I/O on a single storage unit. Which IBM solution would provide that capability at the lowestcost?()A、 IBM XIV Storage System B、 IBM System Storage DS8700 C、 IBM System Storage N6070 D、 IBM System Storage N6210

考题 A customer wants to consolidate storage from four IBM System p servers and one large IBM System i server. The customer does not have a SAN installed. The customer will require approximately 4 TB for System p and 3 TB for System i. The customer states that performance and isolation of the System i system is most important. Capacity, multi-path access, and replication functions are important for the System p servers.    Which solution best satisfies the customer requirements()A、IBM System Storage DS8100 with 300 GB drives for the System p, 73 GB/15k drives for System i, and advanced functions for System p capacityB、IBM System Storage DS8300 with LPAR, 73 GB/15k drives for System i, and 300 GB drives and advanced functions for System p capacityC、IBM System Storage DS6800 with direct attach, 73 GB/15k drives for System i performance, and 300 GB drives and advanced functions for System pD、IBM System Storage DS6800 with LPAR, 146 GB/15k drives for System i, 500 GB FATA drives for System p

考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()A、RDACB、MPIOC、SSPCD、SDDPCM

考题 An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

考题 A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()A、256B、512C、1024D、2048

考题 A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A、Tivoli Storage ManagerB、Tivoli Storage Productivity Center for DiskC、Tivoli Storage Productivity Center Basic EditionD、Tivoli Storage Productivity Center Standard Edition

考题 A customer has purchased three IBM System Storage DS8300 systems and would like to have their SAN and storage administrator trained. The customer is worried about having much of their staff out of the office at the same time attending courses.  Which training alternative provides the necessary training with the least impact()A、purchase the training CD for the disk subsystem and have the staff do self-paced trainingB、have the IBM Service Support Representative perform the trainingC、contact IBM Education Services for an onsite training classD、send one person at a time to an IBM training session

考题 A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A、the IBM System Storage DS8000 Interoperability MatrixB、the IBM System Storage DS8000 Introduction and Planning GuideC、the IBM System Storage DS8000 Host System Attachment GuideD、the IBM System Storage DS8000 User’s Guide

考题 A customer recently installed new SAN with an IBM System Storage DS8300 and several open systems servers to address a need for storage consolidation and still provide  good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A、Tivoli Storage ManagerB、Total Productivity Productivity Center for DiskC、Total Productivity Center Basic EditionD、Total Storage Productivity Center Standard Edition

考题 What information, in addition to model number and serial number, is necessary to perform featureactivation for the IBM System Storage DS8000?()A、Machine signatureB、Customer numberC、Site locationD、Customer contact number

考题 A customer has the following non-virtualized servers: - three Exchange servers, each with 2.8 TB database  - five System i Domino servers, each with 2 TB database  - 20 TB usable capacitySun/SAP cluster  - 70 TB usable capacity of System p requirement  - annual growth rate of 12 TB usable capacity per year   What is the most cost-effective solution for three years()A、IBM System Storage DS5020 with 300 GB drivesB、IBM System Storage DS5300 with 300 GB drivesC、IBM System Storage DS8700 with 300 GB drivesD、IBM System Storage DS5020 with 1 TB SATA drives

考题 A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()A、What are Disaster RecoveryplansB、What are plans for datamigrationC、What storage system space isavailableD、DoesiSCSI meet the needs

考题 A customer with both IBM servers and storage asked their storage specialist to present updatedinformation on the IBM storage portfolio. The specialist suspects a competitor is actively selling inthis account. Which of the following questions, if asked by the customer, would most likely indicatecompetitive activity?()A、Does the DS8700 offer virtualized arrays? B、How can the IBM SAN Volume Controller work in our environment? C、What is the raw disk capacity of the IBM System Storage DS5300? D、What are the support options available on the IBM System Storage DS5020?

考题 A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A、2B、4C、6D、8

考题 A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A、an IBM System Storage DS8700 with LTO tape driveB、an IBM System Storage DS8700 with FlashCopy ManagerC、an IBM XIV Storage SystemD、an IBM XIV Storage System with SAN Volume Controller

考题 单选题A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()A RDACB MPIOC SSPCD SDDPCM

考题 单选题A customer recently installed new SAN with an IBM System Storage DS8300 and several open systems servers to address a need for storage consolidation and still provide  good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A Tivoli Storage ManagerB Total Productivity Productivity Center for DiskC Total Productivity Center Basic EditionD Total Storage Productivity Center Standard Edition

考题 单选题A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A 2B 4C 6D 8

考题 单选题A customer is currently using a Windows file server to share NFS storage (9 TB) to theirapplication server, and a small SAN to supply block I/O to their database servers (5 TB). As theircurrent hardware is aging they are looking for a new best of breed technology to combine file andblock I/O on a single storage unit. Which IBM solution would provide that capability at the lowestcost?()A  IBM XIV Storage System B  IBM System Storage DS8700 C  IBM System Storage N6070 D  IBM System Storage N6210

考题 单选题A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()A 256B 512C 1024D 2048

考题 单选题What is the minimum connection required for Call Home on an IBM System Storage DS8000?()A ISDN connectionB Analog telephone lineC Ethernet internet connectionD Both an analog telephone line and an ethernet connection

考题 单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A IBM System Storage DS8000: Host Systems Attachment GuideB DS8000 Interoperability MatrixC IBM System Storage DS8000: Introduction and Planning GuideD IBM System Storage Solution Handbook

考题 单选题A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A the IBM System Storage DS8000 Interoperability MatrixB the IBM System Storage DS8000 Introduction and Planning GuideC the IBM System Storage DS8000 Host System Attachment GuideD the IBM System Storage DS8000 User’s Guide

考题 单选题A customer with both IBM servers and storage asked their storage specialist to present updatedinformation on the IBM storage portfolio. The specialist suspects a competitor is actively selling inthis account. Which of the following questions, if asked by the customer, would most likely indicatecompetitive activity?()A Does the DS8700 offer virtualized arrays? B How can the IBM SAN Volume Controller work in our environment? C What is the raw disk capacity of the IBM System Storage DS5300? D What are the support options available on the IBM System Storage DS5020?

考题 单选题A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A Tivoli Storage ManagerB Tivoli Storage Productivity Center for DiskC Tivoli Storage Productivity Center Basic EditionD Tivoli Storage Productivity Center Standard Edition

考题 单选题A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A an IBM System Storage DS8700 with LTO tape driveB an IBM System Storage DS8700 with FlashCopy ManagerC an IBM XIV Storage SystemD an IBM XIV Storage System with SAN Volume Controller

考题 单选题A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A 2B 4C 6D 8