网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
Fusible plugs are installed in fire-tube boilers to ().
A
provide a means of draining the boiler
B
warn the engineer of low water level
C
cool the crown sheet at high firing rates
D
open the burners electrical firing circuits
参考答案
参考解析
解析:
暂无解析
更多 “单选题Fusible plugs are installed in fire-tube boilers to ().A provide a means of draining the boilerB warn the engineer of low water levelC cool the crown sheet at high firing ratesD open the burners electrical firing circuits” 相关考题
考题
Fusible plugs are installed in fire-tube boilers to _____.A.provide a means of draining the boilerB.warn the engineer of low water levelC.cool the crown sheet at high firing ratesD.open the burners electrical firing circuits
考题
The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?A.Fusible links must be replaced if a damper is activatedB.Fusible links are tested by applying a source of heat to themC.Fusible links must be replaced at every inspection for certificationD.A fusible link will automatically open after a fire is extinguished and reset the damper
考题
In a CRS cluster with Standby Servers, which of the following statements are true? ()A、The Standby Server can be installed across the WAN from the active server. B、MS SQL 2000 must be installed for the datastores. C、MS SQL 2000 or MSDE can be installed for the datastores. D、On the Standby Server, you must install the same components that are installed on its corresponding active server. E、The Standby Server can be installed on one of the CallManager servers.F、The active server can be installed on one of the CallManager servers.
考题
A technician plugs a USB device into the computer. The system tray displays a message that reports the device is installed, but may not work properly. Which of the following is the MOST likely cause of the message?()A、The device needs a firmware updateB、The device needs an updated driver installedC、The plugged in device is too slow for the USB port speedD、The device is incompatible with the installed version of Windows
考题
Which of the following should Karen, a technician, use to test a parallel port?()A、Line testerB、MultimeterC、Null modem cableD、Loopback plugs
考题
单选题The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?()A
A fusible link will automatically open after a fire is extinguished and reset the damperB
Fusible links must be replaced at every inspection for certificationC
Fusible links are tested by applying a source of heat to themD
Fusible links must be replaced if a damper is activated
考题
单选题Fusible-link fire dampers are operated by().A
a break-glass and pull-cable systemB
electrical controls on the bridgeC
a mechanical arm outside the vent ductD
the heat of a fire melting the link
考题
单选题The diesel engine exhaust gas bypass, as fitted with some waste heat boilers, is installed to ()A
prevent engine back pressure at heavy loadsB
increase total engine efficiency at low loadsC
prevent boiler corrosion at low engine loadsD
improve engine fuel consumption at any load
考题
单选题Waterside scale in a fire-tube boiler may cause ().A
increased heat transferB
fireside erosionC
high steam demandD
overheated tubes
考题
单选题Fusible-link fire dampers are operated by().A
8the heat of a fire melting the linkB
a break-glass and pull-cable systemC
electrical controls on the bridgeD
a mechanical arm outside the vent duct
考题
单选题During extremely cold weather, while starting an engine, it turns too slowly and fails to startThis problem is most likely the result of ()A
high fuel oil viscosityB
low fuel oil temperatureC
high lube oil viscosityD
energized glow plugs
考题
单选题Boilers and cylinders are().A
raw metallic productsB
finished metallic productsC
consumable productsD
Manufactured goods of large Size
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
remove suspended and precipitated solids from the boiler waterB
completely drain the boiler in an emergency situationC
prevent hardened scale deposits in the water drumD
remove floating impurities from the oily water surface
考题
单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A
firing for extended periods in the low fire modeB
overheating, due to waterside depositsC
varying the water level above the crown sheetD
carrying excessive alkalinity in the boiler water
考题
单选题Fusible plugs are installed in fire-tube boilers to ().A
provide a means of draining the boilerB
warn the engineer of low water levelC
cool the crown sheet at high firing ratesD
open the burners electrical firing circuits
考题
单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()A
cyclone furnace boiler typeB
dry back boiler typeC
water-tube typeD
critical circulation boiler type
考题
单选题Which of the following statements concerning fire-tube boilers is correct?()A
Combustion gases flow through the tubesB
Flames impinge on the tubesC
Combustion occurs in the tubesD
Water flows through the tubes
考题
单选题A technician plugs a USB device into the computer. The system tray displays a message that reports the device is installed, but may not work properly. Which of the following is the MOST likely cause of the message?()A
The device needs a firmware updateB
The device needs an updated driver installedC
The plugged in device is too slow for the USB port speedD
The device is incompatible with the installed version of Windows
考题
单选题Fins are installed on the generating tube surfaces in waste heat boilers to ().A
prevent soot fires in the exhaust systemB
prevent exhaust gas erosion of the tubesC
increase the velocity of exhaust gas flowD
increase the rate of heat transfer
考题
单选题The air reservoirs must have () fitted to prevent rupture in the event of fire.A
high pressure alarmB
fire alarmC
extinguishersD
fusible plugs
考题
单选题Small oil spills on deck can be kept from going overboard by().A
driving wooden plugs into the ventsB
closing the lids on the ventsC
plugging the scuppersD
plugging the sounding pipes
考题
单选题A high temperature alarm or () which will melt is used to guard against the explosion of compressor air pipelines.A
a flame trapB
a relief valveC
a fusible plugD
a bursting cap
考题
单选题The procedures recommended for auxiliary boilers having high salinity include ().A
treating with oxygen scavengersB
securing the boiler and giving it a blowing downC
increasing the pHD
reducing the phosphate level
考题
单选题Auxiliary boilers can be classified as()A
water-tube natural circulation boilersB
fire-tube boilersC
water-tube forced circulation boilersD
all of the above
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
completely drain the boiler in an emergencyB
prevent sludge from forming in the drumC
remove floating impurities from the boiler water surfaceD
remove settled solids from the water drum
考题
单选题Who is in charge of the auxiliary boilers?()A
The chief engineerB
The second engineerC
The third engineerD
The fourth engineer
考题
单选题When a vessel is in dry-dock, the vessel’s engineers should ().A
examine the condition of the propellerB
chip and paint all hull protection zincsC
install new docking plugs in all cofferdamsD
inspect the hull for hogging or sagging
考题
单选题To find the cause of a gasoline engine’s failure to start,you should().A
Break the joint in the fuel line at the engine and let the gas run in the bilgesB
Disconnect the wires at the spark plugs and make the spark jump the gapC
Prime the engine with ether through spark plug openingsD
Ventilate the space,then check the battery,spark plugs,carburetor,and fuel line
热门标签