If the head pressure of a reciprocating refrigeration compressor is excessive, ().
A
the relief valve should open before the high pressure cutout
B
the relief valve should open and allow the excess refrigerant to flow to the receiver
C
the high pressure cutout switch should operate before the relief valve opens
D
you should close in on the suction valve
参考答案
参考解析
解析:
暂无解析
更多 “单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve” 相关考题
考题
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
考题
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A
pressurestatB
high pressure cutoutC
solenoid valveD
low pressure cutout switch
考题
单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A
increase the flow of the cooling water through the condenserB
adjust the high pressure cutout to maintain the desired pressureC
open the hot gas bypass temporarily to reduce capacityD
purge non-condensable gases to reduce the excess pressure
考题
单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A
compressor;condenserB
condenser;evaporatorC
throttle valve;evaporatorD
evaporator;condenser
考题
单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A
restriction in refrigerant pipingB
air and non-condensable gases in the condenserC
water in the refrigerantD
flooding back of liquid refrigerant from the evaporator
考题
单选题() provides the head or pressure to supply the domestic water where required.A
The compressed airB
The compressing airC
The transfer pumpD
The head tank
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题Which of the following statements represents the advantage of rotary pumps as compared to reciprocating pumps?()A
The high discharge pressure of the rotary pumps permits a larger volume of fluid per unit time than the reciprocating pumpB
Rotary pumps are capable of pumping more fluid than reciprocating pumps of the same weightC
Rotary pumps occupy only one-half the space of reciprocating pumpsD
Rotary pumps eliminate discharge slippage of the pumped liquid, while this does not hold true for a reciprocating pump
考题
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A
purge the condenser if the waterside is dirtyB
check for proper water flow through the condenserC
increase the high pressure cutout settingD
reduce the cooling water flow
考题
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A
system was overcharged with refrigerantB
high pressure switch was improperly adjustedC
expansion valve strainers were fouledD
suction valves were leaking slightly
考题
单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A
increaseB
reduceC
maintain constantD
None of the above is true
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A
the compressor short cycling on high pressure cut out switchB
high suction pressureC
high head pressureD
bubbles in the sight glass
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A
high pressure liquid lineB
low pressure liquid lineC
high pressure vapor lineD
low pressure vapor line
考题
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A
Condenser and thermal expansion valveB
King and solenoid valvesC
Compressor and thermal expansion valveD
Condenser and solenoid valve
考题
单选题One cause of high head pressure occurring in a refrigeration system can be ().A
insufficient cooling water flow to the condenserB
a low refrigerant charge in the systemC
the liquid valve is open too muchD
high evaporator superheat
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()A
solenoid valveB
low pressure cutout switchC
king valveD
thermal expansion valve
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
考题
单选题Bad valves operation of the reciprocating air compressors can be detected by observation of ().A
the discharge temperature lowB
the discharge temperature highC
the discharge pressure riseD
the inter-stage pressure low
考题
单选题The amount of fluid delivered by a reciprocating pump can be regulated by ().A
throttling the pressure lineB
changing the speed of the pistonC
either A or BD
None of the above is tree
考题
单选题The volute of centrifugal pump also acts as a diffuser converting ()into pressure head.A
mechanical energyB
heat energyC
potential energyD
kinetic head