If a compressor runs continuously, the cause might be a()
A

defective thermal bulb

B

clogged scale trap

C

stuck high-pressure switch

D

stuck low-pressure switch


参考答案

参考解析
解析: 暂无解析
更多 “单选题If a compressor runs continuously, the cause might be a()A defective thermal bulbB clogged scale trapC stuck high-pressure switchD stuck low-pressure switch” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period

考题 Badly leaking refrigeration compressor discharge valves will cause ______.A.overfeeding of the expansion valveB.damage to the condenserC.constant running of the compressorD.flooding of the receiver

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

考题 What is the most probable cause of reduced capacity in a reciprocating air compressor ________.A.Carbon on cylinder headsB.Faulty unloaderC.Leaking air valvesD.Plugged air cooler

考题 单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A Shortage of refrigerant oilB Slight shortage of refrigerantC Excessive condenser cooling water flowD Faulty expansion valve

考题 单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A Closing of the solenoid valveB Closing of the expansion valveC An increase in the suction pressureD Decreasing the suction pressure

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题If the compressor runs continually, the cause might be the()A high-pressure cutout switch is jammed openB low-pressure switch is jammed shutC thermal bulb is not operating properlyD scale trap is clogged

考题 单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()A too much cooling water going through the condenserB not enough refrigerant in the systemC a leak in the evaporator coilsD no enough cooling water going through the condenser

考题 单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A a shortage of compressor oilB warm food in the refrigeratorC excessive condenser cooling waterD a shortage of refrigerant

考题 单选题Badly leaking refrigeration compressor discharge valves will cause().A overfeeding of the expansion valveB damage to the condenserC constant running of the compressorD flooding of the receiver

考题 单选题A warmer than normal compressor suction line might be caused by ().A insufficient lubricationB insufficient refrigerantC excess refrigerantD excessive opening of the expansion valve

考题 单选题What is the result()?A  The program runs and prints “ I = 1 , j = 0”B  The program runs and prints “ I = 1 , j = 4”C  The program runs and prints “ I = 3 , j = 4”D  The program runs and prints “ I = 3 , j = 0”E  An error at line 4 cause compilation to fail.F  An error at line 7 cause compilation to fail.

考题 单选题What is the result?()A  The program runs and prints nothing.B  The program runs and prints “Equal”.C  An error at line 5 cause compilation to fail.D  The program runs but aborts with an exception.

考题 单选题Broken valve strips in an operating low pressure, air compressor will cause ().A an immediate crankcase explosionB oil contamination in the compressed airC a decrease in compressor capacityD no immediate loss of the compressed air capacity

考题 单选题If the electric motor driving an air compressor fails to start, the cause may be a ().A leaking unloaderB tripped circuit breakerC control line leakD defective pop valve

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题If a reciprocating air compressor has a knock occurring in frequency with its operating RPM, the cause is probably ().A misalignment or worn main bearingsB insufficient cylinder lubricationC defective or poorly fitted valvesD all of the above

考题 单选题In the geography class, the teacher explained wind and water might cause soil()A pollutionB excellenceC explosionD erosion

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A has continuously for a long periodB suction pressure is below normalC oil level is below normalD starts after a long idle period