Which will cause the high pressure cutout to stop the compressor in a R-22 system?()
A
Condenser leakage
B
A shortage of liquid refrigerant
C
Excessive frost on the evaporator
D
Not enough condenser cooling water
参考答案
参考解析
解析:
暂无解析
更多 “单选题Which will cause the high pressure cutout to stop the compressor in a R-22 system?()A Condenser leakageB A shortage of liquid refrigerantC Excessive frost on the evaporatorD Not enough condenser cooling water” 相关考题
考题
If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout
考题
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
考题
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
考题
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
考题
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
考题
Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line
考题
Which statement about inert gas pressures in a cargo tank is TRUE ________.A.The pressures of the inert gas in the tank may create excessive pressure at the pump while dischargingB.Gas pressures should be maintained at the highest permissible level throughout the discharging processC.High gas pressures may cause pyrophoric oxidation in the tankD.High gas pressures may cause loss of suction when stripping
考题
单选题Which of the conditions listed would cause simultaneous high cylinder firing pressure and low exhaust temperature?()A
Improper fuel rack positioningB
Lengthy opening of the exhaust valveC
Excessively early injection timingD
Extended light load operation
考题
单选题The device used for low-pressure control and high-pressure cutout on a compressor is called a()A
cutoutB
pressure controllerC
controller switchD
cutout switch
考题
单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()A
Worn intake valve guidesB
Pitted pre-combustion chambersC
Loose valve tappetsD
High exhaust back pressure
考题
单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A
increase the flow of the cooling water through the condenserB
adjust the high pressure cutout to maintain the desired pressureC
open the hot gas bypass temporarily to reduce capacityD
purge non-condensable gases to reduce the excess pressure
考题
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A
the compressor suction pressure is not too highB
all air is purged from the pump and charging fittingsC
the high pressure cutout switch is held open to prevent accidental startingD
the condenser is completely shutdown first
考题
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A
purge the condenser if the waterside is dirtyB
check for proper water flow through the condenserC
increase the high pressure cutout settingD
reduce the cooling water flow
考题
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A
system was overcharged with refrigerantB
high pressure switch was improperly adjustedC
expansion valve strainers were fouledD
suction valves were leaking slightly
考题
单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A
system was overcharged with refrigerantB
system was low on refrigerantC
suction valves were leaking slightlyD
relief valve was leaking slightly
考题
单选题If the compressor runs continually, the cause might be the()A
high-pressure cutout switch is jammed openB
low-pressure switch is jammed shutC
thermal bulb is not operating properlyD
scale trap is clogged
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A
a shortage of refrigerantB
the compressor running continuouslyC
liquid refrigerant returning to the compressorD
the compressor short cycling on the high pressure cutout
考题
单选题If the head pressure is too high,()A
the relief valve should open before the high-pressure cutoutB
the relief valve should open and let excess refrigerant go to receiverC
the high-pressure cutout switch should operate before the relief valve opensD
close in on the suction valve
考题
单选题Which of the following would not cause high suction pressure?()A
insufficient refrigerationB
leaky suction valvesC
expansion valve stuck openD
suction valve not adjusted properly
考题
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A
system is overcharged with refrigerantB
system is low on refrigerantC
discharge valves are leaking excessivelyD
discharge valves are leaking slightly
考题
单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA
any of (1) and (3)B
any of (1) and (2)C
any of (2) and (3)D
any of (1), (2) and (3)
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题If a compressor runs continuously, the cause might be a()A
defective thermal bulbB
clogged scale trapC
stuck high-pressure switchD
stuck low-pressure switch
考题
单选题Fuels of high quality with their earlier ignitions will cause higher ()pressure in cylinders of a diesel engine.A
compressionB
maximumC
ratedD
oil