网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
For proper operation, auxiliary boiler feed water must have which of the following characteristics?()
A
High oxygen concentration
B
Low pH
C
Proper alkalinity
D
All of the above
参考答案
参考解析
解析:
暂无解析
更多 “单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()A High oxygen concentrationB Low pHC Proper alkalinityD All of the above” 相关考题
考题
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()
A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
考题
The water in an auxiliary boiler should be tested for chloride content to determine ( ).A.total dissolved solidsB.salt contaminationC.water harcnessD.chlorine contamination
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness
考题
单选题The most common cause of scale formation in an auxiliary boiler is ()A
concentrations of calcium sulfate in the boiler waterB
fuel oil in the feed waterC
improper treatment of the feed water with calcium sulfateD
excessive feed water alkalinity
考题
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A
in the event of a flame failureB
in the event of a stack fireC
when the water level reach the crown sheetD
when the feed pump discharge pressure drops to a preset minimum
考题
单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A
relieve excess fuel oil pressure during the “off” fire cycleB
admit water to the dry pipeC
throttle the forced draft fan output for proper combustionD
reduce excess steam pressure in the boiler
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A
operating the boiler at less than normal water levelB
installing fins on the firesides of water-tubesC
increasing the amount of excess air to the burnersD
treating the boiler water with chemical oxygen scavengers
考题
单选题The boiler feed water check valves are located on the ()A
feed pump suction lineB
hot wellC
shell of the feed heaterD
feed lines to the boiler
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
remove suspended and precipitated solids from the boiler waterB
completely drain the boiler in an emergency situationC
prevent hardened scale deposits in the water drumD
remove floating impurities from the oily water surface
考题
单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A
firing for extended periods in the low fire modeB
overheating, due to waterside depositsC
varying the water level above the crown sheetD
carrying excessive alkalinity in the boiler water
考题
单选题The water in an auxiliary boiler should be tested daily for ().A
dissolved oxygenB
chloridesC
sludgeD
dissolved nitrogen
考题
单选题A feed pump for an auxiliary boiler might lose suction if the ().A
boiler water level is lowB
feedwater is too hotC
boiler steam demand is lowD
feedwater is too cold
考题
单选题All of the followings are the detainable deficiencies under the SOLAS Convention expert().A
Failure of proper operation of propulsion and other essential machinery, as well as electrical installationB
Failure of the proper operation of the main and auxiliary steering gearC
Failure of engineering watch arrangements to confirm to the requirements specified for the ship by AdministrationD
Failure of the proper operation of emergency generator, lighting, batteries and switches
考题
单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()A
High oxygen concentrationB
Low pHC
Proper alkalinityD
All of the above
考题
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A
ensure feed water flow into the boilerB
keep the steam drum pressure highC
prevent water hammer in the feed lineD
help the feed water flash to steam
考题
单选题The water level in a steaming auxiliary boiler will always ()A
rise when the steam pressure is increasedB
remain constant as long as the feed pump operatesC
fall when the steam pressure is decreasedD
vary as the steam demand changes
考题
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A
precipitate silica from solutionB
reduce corrosion in the heating coilC
prevent clogging and erosion in the coilD
maintain zero water hardness
考题
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A
increased fuel consumptionB
increased feed water consumptionC
fuel pump failureD
combustion control system failure
考题
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A
caustic embrittlement of the boiler metalB
acidic corrosion of the boiler metalC
hard scale deposits on the boiler tubesD
etching of the heat exchange surfaces
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
completely drain the boiler in an emergencyB
prevent sludge from forming in the drumC
remove floating impurities from the boiler water surfaceD
remove settled solids from the water drum
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
考题
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A
10B
7C
4D
1
考题
单选题The water in an operating auxiliary boiler should be tested for alkalinity and chloride content each().A
hourB
dayC
weekD
month
考题
单选题If an operating auxiliary boiler has a water pH reading of 7, you should ().A
bottom blow the boilerB
treat the water with caustic sodaC
treat the water with chemical scavengersD
reduce the water alkalinity to recommended readings
考题
单选题Which action should be taken when an auxiliary boiler in is operation?()A
Clean all electrical connectionsB
Lift the relief valves by handC
Inspect and clean all solenoid valvesD
Inspect for oil and water leaks