网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()
A

suction service valve as a vapor

B

suction service valve as a liquid

C

discharge service valve as a vapor

D

charging valve as a liquid


参考答案

参考解析
解析: 暂无解析
更多 “单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A suction service valve as a vaporB suction service valve as a liquidC discharge service valve as a vaporD charging valve as a liquid” 相关考题
考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid

考题 In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor

考题 Sludge may be formed in the oil in the crankcase of a reciprocating air conditioning compressor as a result of ______.A.refrigerant bubbles in the lube oilB.refrigerant reducing the lube oil viscosityC.oxidation(氧化) of the lube oil from overheatingD.reducing the floc or cloud point of the oil

考题 In an air conditioning system, moisture is removed from the air by ______.A.filtersB.separatorsC.ducted trapsD.dehumidifiers

考题 According to this passage, which of the following statements is true?A.In boiler and machinery spaces, there is the air conditioning.B.In the boiler rooms the requirement of air volume should meet 25-50% of combustion requirement.C.To maintain the comfort zone in the separate control room the air conditioning plant should be fitted.D.The comfort conditions can be maintained in the engine room all the time.

考题 Would you like the air-conditioning on?的意思是:()?

考题 What kind of products do the air carriers deliver? ()A、The high valueB、Low density or weightC、A and BD、To add cost

考题 单选题The sudden reduction of pressure occurring within the crankcase of a refrigeration compressor during starting causes the ().A sudden evaporation of wax crystals in the lubricantB sudden evaporation of entrapped air in the lubricantC release of refrigerant from the oil/refrigerant mixtureD release of dissolved lubricant from the refrigerant

考题 单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A broken valve springsB tight drive beltsC high line voltageD air in the system

考题 单选题In an air conditioning system, moisture is removed from the air by()A filersB separatorsC ducted trapsD dehumidifiers

考题 单选题A re-heater in an air conditioning system functions to ().A control inlet air temperatureB control inlet air volumeC maintain relative humidity at 15%D restore conditioned air temperature to a comfortable level

考题 单选题A re-heater, as used in an air conditioning system, is designed to control the ()A chilled water temperatureB dew point temperatureC primary air temperatureD dry bulb temperature

考题 单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().A liquid strainerB refrigerant inlet of the condenserC inlet side of the evaporatorD suction side of the compressor

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题Which of the fluids listed is normally used to condense the primary refrigerant in a shipboard central air conditioning system?()A Air or NitrogenB Seawater or Fresh waterC Sodium Nitrate brineD Calcium Sulfate brine

考题 单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().A increasing refrigerant pressure in the coilB increasing chilled water flow through the coolerC sub-cooling the refrigerant in the condenserD superheating the refrigerant in the compressor

考题 单选题Air conditioning is the process of treating air to control () its temperature, humidity, cleanliness and distribution to meet the comfort requirements of the occupants of the conditioned space.A instantaneousB instantaneouslyC simultaneousD simultaneously

考题 单选题In reference to air conditioning, when air attains the maximum amount of moisture it can hold at a specific temperature, it is said to be ().A superheatedB saturatedC condensedD convected

考题 单选题In order to distribute the side pressures over a wide area of the cylinder walls and liners, which of the listed types of pistons are used in modem low pressure air compressors?()A DifferentialB TrunkC BarrelD Valve-in-head

考题 单选题With ducted air conditioning systems, the modern tendency is to use()A central air conditioning systemB high velocity systemC low velocity systemD single duct system

考题 单选题To add refrigerant to the high side of an air conditioning system, you should introduce the refrigerant through the ().A discharge service valve as a vaporB suction service valve as a liquidC charging valve as a liquidD condenser purge valve as a vapor

考题 单选题To prevent the unnecessary loading of an air conditioning system while maintaining the designed dry bulb temperature and relative humidity in an air conditioning system, you should ()A admit only enough fresh outside air to provide proper ventilationB reduce the air reheating system loadC lower the compressor head pressureD operate the purge recovery unit continuously

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()A purge lube oil from the liquid refrigerantB recover water purged from the systemC separate foul gases from the receiverD purge non-condensable gases without losing refrigerant

考题 单选题The quantity of cooled air delivered by an air conditioning unit should () the sum of the quantity of air re-circulated to the unit and the quantity mechanically exhausted.A balanceB not balanceC be more thanD be less than