网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility.  What other product is required to accomplish this objective? ()
A

 HACMP for AIX

B

 PowerVM Enterprise Edition

C

 IBM Management Edition for AIX

D

 Workload Partition Manager for AIX


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility.  What other product is required to accomplish this objective? ()A  HACMP for AIXB  PowerVM Enterprise EditionC  IBM Management Edition for AIXD  Workload Partition Manager for AIX” 相关考题
考题 There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives.Which of the following is the MOST likely cause?()A. A failed RAID controllerB. Two failed processorsC. Two failed sticks of memoryD. Two failed drives

考题 A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers.What configuration setting does the storage specialist need to highlight?()A. increase the buffer credits on the HBAsB. increase the number of device logins on the ESX serversC. additional paths will be required between the servers and storageD. multipath option on the ESX servers should be changed to round-robin

考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation.What multipathing driver is required to build a redundant solution?()A.RDACB.MPIOC.SSPCD.SDDPCM

考题 A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A、One fibre channel switchB、Two fibre channel switchesC、Two Ethernet cardsD、Nothing

考题 A customer has a p650 on order and plans to put it in a current OEM rack.  They are concerned that the p650 power supply may demand more current than the OEM PDU can provide.  Which planning guide specification would provide the necessary requirements?()A、VoltageB、FrequencyC、Power Source Loading (max)D、Power Source Loading (typical)

考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()A、RDACB、MPIOC、SSPCD、SDDPCM

考题 There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives.  Which of the following is the MOST likely cause?()A、 A failed RAID controllerB、 Two failed processorsC、 Two failed sticks of memoryD、 Two failed drives

考题 retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere.Which of the following should be discussed with this customer? ()A、Is the web content static or dynamic information B、Consider two servers for redundancy and failover C、What is the average CPU utilization of the existing web servers D、Will the servers need a SCSI or Fibre Channel storage solution

考题 Which feature of the IBM p5 servers enables customers to be confident that data within two distinct partitions on the server will be isolated?()A、POWER HypervisorB、Virtual LANC、POWER5 processorD、Redundant Power and Cooling

考题 A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()A、increase the buffer credits on the HBAsB、increase the number of device logins on the ESX serversC、additional paths will be required between the servers and storageD、multipath option on the ESX servers should be changed to round-robin

考题 A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700.  They would like to upgrade and plan for 40 TB capacity.  The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()A、What are the plans for Disaster Recovery? B、What are the plans for data migration? C、Would iSCSI meet your needs? D、How much space is available in the current storage systems?

考题 A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility.  What other product is required to accomplish this objective? ()A、 HACMP for AIXB、 PowerVM Enterprise EditionC、 IBM Management Edition for AIXD、 Workload Partition Manager for AIX

考题 A customer has two locations that host their pSeries servers.  Traffic is being routed through the public Internet.  The customer needs to exchange confidential financial data between the servers.  Which of the following solutions should the pSeries technical specialist propose to the customer to secure the data?()A、A DCE domainB、A Kerberos domainC、A PPP tunnel between the serversD、An IPSEC tunnel between the servers

考题 A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()A、Redundant power supplies on the serversB、Redundant PDUs in the rackC、edundant power supplies in the servers and redundant PDUs in the rackD、Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)

考题 A customer requires two 12X loops on their new POWER7 system. What is the smallest system that will support two loops?()A、Power 710B、Power 720C、Power 730D、Power 740

考题 A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()A、Purchase a second HMC and use this to manage the new servers.B、Connect all of the new servers to the existing private HMC network.C、Configure a second private network on their existing HMC for the new servers.D、Connect 9 of the new servers to the existing HMC and use Integrated Virtualization Manager on the 10th.

考题 A retail customer is looking at ways to reduce power requirements. They are considering deploying two hundred IBM HS22 blades running Red Hat Linux in the IBM BladeCenter E chassis. The customer has already chosen Intel L5640 CPUs to reduce power. Which on-board storage option allows the customer to reduce power consumption of each blade?()A、One 50 GB SATA 1.8 inch SSDB、Two 73GB 10K SAS HDD SFFC、Two 31 GB SATA 2.5 inch SSDD、Two 50GB SATA 1.8 inch SSD

考题 A retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere. Which of the following should be discussed with this customer?()A、Consider two servers for redundancy and failoverB、Web content static or dynamic informationC、Processor utilization of the existing web serversD、SCSI orFibre Channel storage solution

考题 A customer is configuring Live Partition Mobility on two POWER6-based servers,  Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()A、 IBM Director connectionB、 Dynamic LPAR Resource Manager (DLRM)C、 Barrier Synchronization Register Device (BSR)D、 Virtual Asynchronous Services Interface (VASI)

考题 A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()A、What are Disaster RecoveryplansB、What are plans for datamigrationC、What storage system space isavailableD、DoesiSCSI meet the needs

考题 An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()A、Power 770 serversB、Power 750 serversC、Power 755 serversD、Power 720 servers

考题 单选题A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility.  What other product is required to accomplish this objective? ()A  HACMP for AIXB  PowerVM Enterprise EditionC  IBM Management Edition for AIXD  Workload Partition Manager for AIX

考题 单选题A customer is configuring Live Partition Mobility on two POWER6-based servers,  Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()A  IBM Director connectionB  Dynamic LPAR Resource Manager (DLRM)C  Barrier Synchronization Register Device (BSR)D  Virtual Asynchronous Services Interface (VASI)

考题 单选题retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere.Which of the following should be discussed with this customer? ()A Is the web content static or dynamic information B Consider two servers for redundancy and failover C What is the average CPU utilization of the existing web servers D Will the servers need a SCSI or Fibre Channel storage solution

考题 单选题A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet the customer requirements while reducing single points of failure?()A AB BC CD D

考题 单选题A customer has two locations that host their pSeries servers.  Traffic is being routed through the public Internet.  The customer needs to exchange confidential financial data between the servers.  Which of the following solutions should the pSeries technical specialist propose to the customer to secure the data?()A A DCE domainB A Kerberos domainC A PPP tunnel between the serversD An IPSEC tunnel between the servers

考题 单选题A small IT department is deploying Power 720 servers exploiting virtualization technologies.  Each Power 720 will have two partitions, one with 6 cores and one with 2 cores, and both partitions having 32GB of memory each. Live Partition Mobility is being considered at some point in the future. What is the minimum AIX Edition required to support the customer?()A AIX Basic EditionB AIX Express EditionC AIX Standard EditionD AIX Enterprise Edition

考题 单选题A new p5 customer has just installed a partitioned p5-550 alongside some older POWER4 servers.  The pSeries technical specialist has received a call to say that the existing HMC (7315) cannot connect to the new server.  How can the specialist help the customer?()A Explain to the customer that they need an additional HMC for the POWER5 system.B Obtain a PO from the customer to purchase additional serial connections to the HMC.C Obtain a PO from the customer to purchase additional Ethernet connections to the HMC.D Explain to the customer that they need a firmware update on the HMC to support both POWER4 and POWER5.