(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.
A

An economizer

B

An attemperator

C

A water dram

D

A down-comer tube


参考答案

参考解析
解析: 暂无解析
更多 “单选题(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.A An economizerB An attemperatorC A water dramD A down-comer tube” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 A bypass line provided around a waste heat auxiliary boiler in a diesel engine exhaust system, may be used to avoid boiler ______.A.corrosion at low engine loadsB.erosion at high engine loadsC.overload at high engine loadsD.scaling at all exhaust temperatures

考题 Which statement about the inert gas system is TRUE ________.A.Boiler soot blowers should never be used when the IG system is operatingB.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very lightC.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very lightD.Flue gas with excessive oxygen content is de-oxygenated in the scrubber

考题 单选题The steam boiler is part of a closed loop steam, whereby, after the energy of the steam is used up and it becomes water again, () is collected and returned back to the boiler for heating up again to steam.A the formerB the firstC the latterD the last

考题 单选题What is NOT a function of the steam drum of a marine water-tube boiler().A Receives saturated steam from the generating tubesB Serves as a reservoir of boiler feed waterC Holds internal fittings for separation of moisture from steamD Collects steam exhausted from the turbines

考题 单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A relieve excess fuel oil pressure during the “off” fire cycleB admit water to the dry pipeC throttle the forced draft fan output for proper combustionD reduce excess steam pressure in the boiler

考题 单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC the water tube boiler will cost shorter time for steam raisingD the water tube boiler require lower skill in operating and maintaining

考题 单选题Waterside scale in a fire-tube boiler may cause ().A increased heat transferB fireside erosionC high steam demandD overheated tubes

考题 单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().A steam stop valveB dry pipeC feedwater systemD generating tubes

考题 单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.A main stem stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A monkeyB donkeyC waste heatD main

考题 单选题As an alternative to the conventional seawater cooling system, is based on principles about cooler locations, ()flow control and preheating, but with a central cooler and one additional set of pumps().A the central cooling system, differentB the central cooling system, the sameC the open cooling system, differentD the open cooling system, the same

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题A feed pump for an auxiliary boiler might lose suction if the ().A boiler water level is lowB feedwater is too hotC boiler steam demand is lowD feedwater is too cold

考题 单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A ensure feed water flow into the boilerB keep the steam drum pressure highC prevent water hammer in the feed lineD help the feed water flash to steam

考题 单选题The water level in a steaming auxiliary boiler will always ()A rise when the steam pressure is increasedB remain constant as long as the feed pump operatesC fall when the steam pressure is decreasedD vary as the steam demand changes

考题 单选题Lube oil in the fresh water cooling system of a diesel engine may result from a ()A camshaft seizureB lube oil pump failureC lube oil cooler failureD lube oil pump overflow

考题 单选题() should be tested and adjusted when the boiler survey is carried out.A The boiler oil tankB The steam pipeC The fire sideD The safety valves

考题 单选题Foaming in the steam drum may be caused by () in a boiler.A oxygen in the waterB poor boiler designC density too highD excessive steam demand

考题 单选题The boiler is fired () the demand for steam exceeds that available from exhaust gas heating.A wheneverB howeverC whereverD whether

考题 单选题When steam is being raised on a boiler, the water level will normally ().A drop as the boiler warms upB rise as the boiler warms upC remain unchanged until the boiler is hot enoughD rise and fall with the steam demand

考题 单选题A waste heat boiler is installed on some diesel propelled vessels to ().A provide steam for emergency propulsionB provide steam for the turbo-generatorC heat the waste water tanksD steam for warming engines

考题 单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A high steam pressure in the boilerB abnormally high feed water temperatureC abnormally high boiler water temperatureD steam demand exceeding feed pump capacity

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow

考题 单选题A donkey boiler is ().A one to supply steam to the main propulsion turbineB an auxiliary boilerC A and BD neither A nor B