网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.
A
An economizer
B
An attemperator
C
A water dram
D
A down-comer tube
参考答案
参考解析
解析:
暂无解析
更多 “单选题(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.A An economizerB An attemperatorC A water dramD A down-comer tube” 相关考题
考题
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()
A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
A bypass line provided around a waste heat auxiliary boiler in a diesel engine exhaust system, may be used to avoid boiler ______.A.corrosion at low engine loadsB.erosion at high engine loadsC.overload at high engine loadsD.scaling at all exhaust temperatures
考题
Which statement about the inert gas system is TRUE ________.A.Boiler soot blowers should never be used when the IG system is operatingB.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very lightC.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very lightD.Flue gas with excessive oxygen content is de-oxygenated in the scrubber
考题
单选题The steam boiler is part of a closed loop steam, whereby, after the energy of the steam is used up and it becomes water again, () is collected and returned back to the boiler for heating up again to steam.A
the formerB
the firstC
the latterD
the last
考题
单选题What is NOT a function of the steam drum of a marine water-tube boiler().A
Receives saturated steam from the generating tubesB
Serves as a reservoir of boiler feed waterC
Holds internal fittings for separation of moisture from steamD
Collects steam exhausted from the turbines
考题
单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A
relieve excess fuel oil pressure during the “off” fire cycleB
admit water to the dry pipeC
throttle the forced draft fan output for proper combustionD
reduce excess steam pressure in the boiler
考题
单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A
natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB
for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC
the water tube boiler will cost shorter time for steam raisingD
the water tube boiler require lower skill in operating and maintaining
考题
单选题Waterside scale in a fire-tube boiler may cause ().A
increased heat transferB
fireside erosionC
high steam demandD
overheated tubes
考题
单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().A
steam stop valveB
dry pipeC
feedwater systemD
generating tubes
考题
单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.A
main stem stop valveB
auxiliary steam stop valveC
feed check or control valveD
blow down valve
考题
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A
steam demand is highB
salinity is highC
safety valve simmersD
burner flame is extinguished
考题
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A
monkeyB
donkeyC
waste heatD
main
考题
单选题As an alternative to the conventional seawater cooling system, is based on principles about cooler locations, ()flow control and preheating, but with a central cooler and one additional set of pumps().A
the central cooling system, differentB
the central cooling system, the sameC
the open cooling system, differentD
the open cooling system, the same
考题
单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A
carbon deposits on the flame scannerB
high fuel oil temperatureC
low fuel oil viscosityD
high steam pressure
考题
单选题A feed pump for an auxiliary boiler might lose suction if the ().A
boiler water level is lowB
feedwater is too hotC
boiler steam demand is lowD
feedwater is too cold
考题
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A
ensure feed water flow into the boilerB
keep the steam drum pressure highC
prevent water hammer in the feed lineD
help the feed water flash to steam
考题
单选题The water level in a steaming auxiliary boiler will always ()A
rise when the steam pressure is increasedB
remain constant as long as the feed pump operatesC
fall when the steam pressure is decreasedD
vary as the steam demand changes
考题
单选题Lube oil in the fresh water cooling system of a diesel engine may result from a ()A
camshaft seizureB
lube oil pump failureC
lube oil cooler failureD
lube oil pump overflow
考题
单选题() should be tested and adjusted when the boiler survey is carried out.A
The boiler oil tankB
The steam pipeC
The fire sideD
The safety valves
考题
单选题Foaming in the steam drum may be caused by () in a boiler.A
oxygen in the waterB
poor boiler designC
density too highD
excessive steam demand
考题
单选题The boiler is fired () the demand for steam exceeds that available from exhaust gas heating.A
wheneverB
howeverC
whereverD
whether
考题
单选题When steam is being raised on a boiler, the water level will normally ().A
drop as the boiler warms upB
rise as the boiler warms upC
remain unchanged until the boiler is hot enoughD
rise and fall with the steam demand
考题
单选题A waste heat boiler is installed on some diesel propelled vessels to ().A
provide steam for emergency propulsionB
provide steam for the turbo-generatorC
heat the waste water tanksD
steam for warming engines
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
考题
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A
check and regulate the water levelB
close the air cock once fires are litC
blowdown the gage glassD
crack the steam stop to assure protective steam flow
考题
单选题A donkey boiler is ().A
one to supply steam to the main propulsion turbineB
an auxiliary boilerC
A and BD
neither A nor B
热门标签