单选题
Adequate attention must be given to the water cooling system of the air compressors, for () can cause condensation on the cylinder walls.
A
overcooling
B
poor cooling
C
overloading
D
unloading
参考答案
参考解析
解析:
暂无解析
更多 “单选题Adequate attention must be given to the water cooling system of the air compressors, for () can cause condensation on the cylinder walls.A overcoolingB poor coolingC overloadingD unloading” 相关考题
考题
What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above
考题
If the coolant temperature of a closed cooling water system for a diesel enginegradually increases, the trouble usually is( ).A.a broken shaft on the freshwater pumpB.an excessive accumulation of scale in the heat exchangerC.an incorrect thermostatic element operating rangeD.lube oil in the cooling water
考题
_____ allows for expansion and water make up in the water cooling system.A.A top tankB.A head tankC.A head valveD.A drain tank
考题
High diesel engine cooling water temperatures can be caused by ______.A.air in the cooling systemB.an overhauled water pumpC.correct amount of coolantD.no air in the cooling system
考题
Why is it necessary to have routine testing of the cooling water?A.To ensure that the proper residuals of treatment chemicals, as specified, are maintained all timeB.To trace leakage in the cooling water systemC.It is not necessaryD.To detect the presence of contaminants in the water that may be injurious to the cooling system
考题
单选题In a closed cooling water system, which of the problems can cause the water pressure to fluctuate?()A
An open vent in the cooling systemB
A fouled sea chestC
A restricted water passage in the engineD
Air entrained in the cooling water
考题
单选题The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().A
fresh water expansion tankB
sea water expansion tankC
thermostatic expansion valveD
jacket water cooler accumulator
考题
单选题After "F.W.E" is given, the air system is shut down, the () gear put in, all drains and indicator cocks opened, and the cooling water kept running.A
steeringB
timingC
turningD
running
考题
单选题If the jacket water temperature in an auxiliary diesel engine cooling system is lower than normal, the probable cause is ()A
air binding of the engine cooling systemB
a cracked water cooled exhaust manifoldC
blockage in the heat exchangerD
faulty operation of the thermostat
考题
单选题Where is the cooling water from the compensating tank in the cooling water system of main engine lead to?()A
discharge side of the centrifugal pumpB
suction side of the centrifugal pumpC
the lowest point of the cooling water systemD
inlet of the main engine
考题
单选题() allows for expansion and water make up in the water cooling system.A
A top tankB
A head tankC
A head valveD
A drain tank
考题
单选题High diesel engine cooling water temperatures can be caused by ().A
air in the cooling systemB
an overhauled water pumpC
correct amount of coolantD
no air in the cooling system
考题
单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()A
improper venting of the cooling systemB
carrying the expansion tank water level too highC
a totally clogged impeller in the cooling water pumpD
an incorrectly set cooling system temperature control
考题
单选题The expansion tank for a diesel engine closed cooling system is designed to maintain a constant head on the system and ().A
reduce water temperatureB
reduce water turbulenceC
provide an air cushionD
allow for an increase in water volume as the engine warms up
考题
单选题After the order “()” is given, the air system is shut down, the turning gear put in, all drains and indicator cocks opened, and the cooling water and lubricating oil systems kept running.A
Stand-by EngineB
Stop EngineC
Finished With EngineD
Dead Slow Ahead
考题
单选题The highest pressure in any closed diesel engine freshwater cooling system is at the ().A
jacket water outletB
expansion tank inletC
heat exchanger inletD
cooling water pump outlet
考题
单选题As to the piston cooling, of the following, which statement is not true?()A
Because the piston is exposed to very high temperature, it must be cooledB
The lower the piston cooling temperature is, the better it isC
Both water and lube oil can be used as coolantD
One of the piston cooling methods is vibration cooling, with better effect
考题
单选题Which of the following statements is correct concerning diesel engine cooling water systems?()A
Each engine must have its own engine driven cooling water pump capable of providing cooling for all ranges of operationB
propulsion engines with bores exceeding 200 mm are to be fitted with a means to display the cooling water temperature of each cylinderC
At least two independent sea suctions are to be provided for supplying water to the engine jackets or to the heat exchangersD
Suitable strain are to be fitted between the circulating pumps and heat exchangers when sea water is used for direct cooling
考题
单选题In a diesel engine jacket water cooler, with seawater cooling the fresh water, the()A
sea water temperature must never be warmer than 40℃B
jacket water pressure should always be greater than the sea water pressureC
jacket water temperature must always be less than 60℃D
jacket water pressure must always be less than the sea water pressure
考题
单选题If the water level dropped rapidly in the expansion tank of a closed diesel engine cooling water system, you should suspect a ().A
loss of suction in the circulating pumpB
leak in the primary cooling systemC
broken raw water pump shaftD
burned or cracked piston in one cylinder
考题
单选题Which of the following problems can cause fluctuating pressures in the closed cooling system of a main propulsion diesel engine?()A
Defective temperature controls in the systemB
Cavitation in the cooling water pumpC
Opened vent in the cooling systemD
Restricted water passages in the engine
考题
单选题Temperature control valves installed in the jacket cooling water system of a diesel engine modulates the rate of water flow through the ().A
cooling water pumpB
nozzle cooling passagesC
cylinder jacketsD
heat exchanger
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
考题
单选题Which of the following statements is correct for the design and installation of diesel engine cooling water systems?()A
An alarm device with audible and visible signals is required for all cooling water systemsB
Propulsion engines with bores over 200 mm are to be fitted with cooling water jacketsC
Each totally enclosed cooling system shall be provided with a suitable head tankD
Drain cocks are to be provided at the lowest points of all cylinder water jackets
考题
单选题In a diesel engine cooling water system, a pH of 60 indicates a/an ().A
slightly acidic conditionB
slightly alkaline conditionC
overtreatment of waterD
neutral condition of water
考题
单选题In the process of the stand-by, warm-up the engine usually through give preheat of which parts of the diesel engine?()A
cooling water of the cooling systemB
fuel of the FO systemC
LO of the LO systemD
cooling water of the cooling system and LO of the LO system
考题
单选题If the compressor-discharge temperature is higher than the receiver temperature()A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some of the refrigerant from the system