To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()
A
suction service valve as a vapor
B
suction service valve as a liquid
C
discharge service valve as a vapor
D
charging valve as a liquid
参考答案
参考解析
解析:
暂无解析
更多 “单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A suction service valve as a vaporB suction service valve as a liquidC discharge service valve as a vaporD charging valve as a liquid” 相关考题
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid
考题
In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor
考题
Sludge may be formed in the oil in the crankcase of a reciprocating air conditioning compressor as a result of ______.A.refrigerant bubbles in the lube oilB.refrigerant reducing the lube oil viscosityC.oxidation(氧化) of the lube oil from overheatingD.reducing the floc or cloud point of the oil
考题
In an air conditioning system, moisture is removed from the air by ______.A.filtersB.separatorsC.ducted trapsD.dehumidifiers
考题
According to this passage, which of the following statements is true?A.In boiler and machinery spaces, there is the air conditioning.B.In the boiler rooms the requirement of air volume should meet 25-50% of combustion requirement.C.To maintain the comfort zone in the separate control room the air conditioning plant should be fitted.D.The comfort conditions can be maintained in the engine room all the time.
考题
What kind of products do the air carriers deliver? ()A、The high valueB、Low density or weightC、A and BD、To add cost
考题
单选题The sudden reduction of pressure occurring within the crankcase of a refrigeration compressor during starting causes the ().A
sudden evaporation of wax crystals in the lubricantB
sudden evaporation of entrapped air in the lubricantC
release of refrigerant from the oil/refrigerant mixtureD
release of dissolved lubricant from the refrigerant
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题In an air conditioning system, moisture is removed from the air by()A
filersB
separatorsC
ducted trapsD
dehumidifiers
考题
单选题A re-heater in an air conditioning system functions to ().A
control inlet air temperatureB
control inlet air volumeC
maintain relative humidity at 15%D
restore conditioned air temperature to a comfortable level
考题
单选题A re-heater, as used in an air conditioning system, is designed to control the ()A
chilled water temperatureB
dew point temperatureC
primary air temperatureD
dry bulb temperature
考题
单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().A
liquid strainerB
refrigerant inlet of the condenserC
inlet side of the evaporatorD
suction side of the compressor
考题
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A
maintain adequate coil back pressureB
prohibit flashing in the liquid lineC
reduce refrigerant volume in the systemD
reduce compressor discharge line loading
考题
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A
passing it through the expansion valveB
condensing refrigerant in the system condenserC
passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD
maintaining a high pressure on the systems receiver
考题
单选题Which of the fluids listed is normally used to condense the primary refrigerant in a shipboard central air conditioning system?()A
Air or NitrogenB
Seawater or Fresh waterC
Sodium Nitrate brineD
Calcium Sulfate brine
考题
单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().A
increasing refrigerant pressure in the coilB
increasing chilled water flow through the coolerC
sub-cooling the refrigerant in the condenserD
superheating the refrigerant in the compressor
考题
单选题Air conditioning is the process of treating air to control () its temperature, humidity, cleanliness and distribution to meet the comfort requirements of the occupants of the conditioned space.A
instantaneousB
instantaneouslyC
simultaneousD
simultaneously
考题
单选题In reference to air conditioning, when air attains the maximum amount of moisture it can hold at a specific temperature, it is said to be ().A
superheatedB
saturatedC
condensedD
convected
考题
单选题In order to distribute the side pressures over a wide area of the cylinder walls and liners, which of the listed types of pistons are used in modem low pressure air compressors?()A
DifferentialB
TrunkC
BarrelD
Valve-in-head
考题
单选题With ducted air conditioning systems, the modern tendency is to use()A
central air conditioning systemB
high velocity systemC
low velocity systemD
single duct system
考题
单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A
suction service valve as a vaporB
suction service valve as a liquidC
discharge service valve as a vaporD
charging valve as a liquid
考题
单选题To add refrigerant to the high side of an air conditioning system, you should introduce the refrigerant through the ().A
discharge service valve as a vaporB
suction service valve as a liquidC
charging valve as a liquidD
condenser purge valve as a vapor
考题
单选题To prevent the unnecessary loading of an air conditioning system while maintaining the designed dry bulb temperature and relative humidity in an air conditioning system, you should ()A
admit only enough fresh outside air to provide proper ventilationB
reduce the air reheating system loadC
lower the compressor head pressureD
operate the purge recovery unit continuously
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()A
purge lube oil from the liquid refrigerantB
recover water purged from the systemC
separate foul gases from the receiverD
purge non-condensable gases without losing refrigerant
考题
单选题The quantity of cooled air delivered by an air conditioning unit should () the sum of the quantity of air re-circulated to the unit and the quantity mechanically exhausted.A
balanceB
not balanceC
be more thanD
be less than