网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()
A

increase the buffer credits on the HBAs

B

increase the number of device logins on the ESX servers

C

additional paths will be required between the servers and storage

D

multipath option on the ESX servers should be changed to round-robin


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()A increase the buffer credits on the HBAsB increase the number of device logins on the ESX serversC additional paths will be required between the servers and storageD multipath option on the ESX servers should be changed to round-robin” 相关考题
考题 A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers.What configuration setting does the storage specialist need to highlight?()A. increase the buffer credits on the HBAsB. increase the number of device logins on the ESX serversC. additional paths will be required between the servers and storageD. multipath option on the ESX servers should be changed to round-robin

考题 A customer has a very large number of physical Windows-based servers and no centralized storage. Which technology solution will help the customer to reduce the footprint of their existing server estate?()A. z/OS, DS8000, TSMB. TSM, LTO-5, VMwareC. System x, VMware, XIVD. System p, VMware, DS5000

考题 A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A、One fibre channel switchB、Two fibre channel switchesC、Two Ethernet cardsD、Nothing

考题 A customer wants to hold all enterprise data on their DS4000 system.  Several servers were added after they purchased another company.  The servers that have to be run are:       (1)An Oracle database running on a HP-UX server   (2)Several virtual machines running on VMWare ESX server       (3)A Microsoft cluster running Exchange 2000 server   Which of these new servers can be integrated with the DS4000?()A、DS4000 storage does not support HP-UX, so the HP-UX server cannot be integrated.All other new servers can be used.B、An Exchange cluster needs local disks, so the DS4000 cannot be used for this.All other new servers can be used.C、When equipped with proper HBA’s and subsystem device drivers, all new servers can operate with the DS4000 storage device.D、VMWare ESX can use the DS4000 storage; however, the virtual machines running in it will not have access to this storage other than via a virtual disk.All other new servers can be used.

考题 A customer is considering replacement of twenty older 4U and 6U rack-based servers with one IBM x366 Server running VMWare ESX attached to one DS4300.  Which of the following represents a reduction in Total Cost of Ownership (TCO) for the customer?()A、Reduction in operating system software licensing and application costsB、Reduction in floor space and hardware cost savingC、VMWare is licensed per system so no extra charge for SMP supportD、No single point of failure, reducing downtime

考题 A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()A、Virtual EthernetB、Micro-PartitioningC、Virtual I/O ServerD、Capped and uncapped partitions

考题 A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()A、add twofibre HBAs to the System i and connect to the SANB、add twofibre HBAs to the System i and connect to the Windows ServersC、add twofibre HBAs to the System i and connect to the System i using VIOSD、add two SAS HBAs to the Systemi array and connect directly to the DS5300

考题 A customer server has the maximum local storage installed. The customer plans to share this new storage with other servers. Which of the following provides that server additional storage?()A、Add External Storage via EXP3000B、Replace current storage with more dense drivesC、Add External Storage via SAND、Add storage expansion blade

考题 A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()A、increase the buffer credits on the HBAsB、increase the number of device logins on the ESX serversC、additional paths will be required between the servers and storageD、multipath option on the ESX servers should be changed to round-robin

考题 A customer currently buys HP ProLiant servers and EMC storage. The customer has encountered various problems getting certain servers to work with their storage.  Which of the following arguments can the Sales Specialist present to best position IBM? ()A、IBM’s ServerProven program is a reference that assures a customer of compatibility with specific third-party products.B、IBM sells other vendors’ products and will test compatibility with the customer’s products. C、B IBM’s storage division regularly tests their products with other vendors’ server products.  D、IBM’s server division regularly tests their products with other vendors’ storage products.

考题 An IBM Business Partner has sold a DS5020 and new IBM SAN switches to replace a customer EMC storage infrastructure. The customer dissatisfaction has arisen during the installation because according to the DS5020 interoperability matrix, two HP Proliant servers running Exchange have FC HBAs that are not supported. Which of the following is the most probable cause of the customer dissatisfaction()A、The EMC storage specialist has not participated in the TDA meetingB、The FC HBAs are 4 Gbps technologyC、The Technical and Delivery Assessment review actions were not executedD、The customer should have checked that the HBAs are supported according to the HP storage interoperability matrix

考题 A customer has a mixed Dell and IBM server environment.  They want to implement a system management solution for all their Windows, Linux, and VMWare ESX Intel based servers.  Which TWO features of IBM Director will be an advantage for this customer?()A、IBM Director comes with free Aurema and SteelEye software plug-ins.B、IBM Director supports non-IBM industry standard Intel based servers.C、IBM Director servers can be managed from within the MS Performance Monitor.D、IBM Director requires no agents to be installed and run on the IBM systems.E、IBM Director offers agents to manage VMWare ESX Server and runs on Linux while Dell does not.

考题 A customer has a very large number of physical Windows-based servers and no centralized storage. Which technology solution will help the customer to reduce the footprint of their existing server estate?()A、z/OS, DS8000, TSMB、TSM, LTO-5, VMwareC、System x, VMware, XIVD、System p, VMware, DS5000

考题 A customer has four 2-way 2U front-end web servers that are currently running at 15% CPU utilization.  These servers provide points of access for users worldwide, and volume is expected to triple in the next six months and aggressively grow thereafter.  They want to upgrade these systems to newer technology and stay within the 8U of rack space that they are replacing.  Which solution would fit the customer’s requirements?()A、Three x366 4-ways running VMWare ESX Server.B、An x445 8-way Xeon MP attached to a DS4300 and running VMWare ESX Server.C、An x445 16-way Xeon MP attached to an EXP400 and running VMWare ESX Server.D、Four x346 2-ways running VMWare ESX Server.

考题 A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()A、Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionB、Add iSCSI cards to the servers and direct attach them to a DS300 dual controller modelC、Use clustered NAS solution with redundant gigabit network connectionsD、Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

考题 单选题A customer currently buys HP ProLiant servers and EMC storage. The customer has encountered various problems getting certain servers to work with their storage.  Which of the following arguments can the Sales Specialist present to best position IBM? ()A IBM’s ServerProven program is a reference that assures a customer of compatibility with specific third-party products.B IBM sells other vendors’ products and will test compatibility with the customer’s products. C B IBM’s storage division regularly tests their products with other vendors’ server products.  D IBM’s server division regularly tests their products with other vendors’ storage products.

考题 单选题A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A One fibre channel switchB Two fibre channel switchesC Two Ethernet cardsD Nothing

考题 单选题A customer server has the maximum local storage installed. The customer plans to share this new storage with other servers. Which of the following provides that server additional storage?()A Add External Storage via EXP3000B Replace current storage with more dense drivesC Add External Storage via SAND Add storage expansion blade

考题 单选题A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()A add twofibre HBAs to the System i and connect to the SANB add twofibre HBAs to the System i and connect to the Windows ServersC add twofibre HBAs to the System i and connect to the System i using VIOSD add two SAS HBAs to the Systemi array and connect directly to the DS5300

考题 单选题A customer has four 2-way 2U front-end web servers that are currently running at 15% CPU utilization.  These servers provide points of access for users worldwide, and volume is expected to triple in the next six months and aggressively grow thereafter.  They want to upgrade these systems to newer technology and stay within the 8U of rack space that they are replacing.  Which solution would fit the customer’s requirements?()A Three x366 4-ways running VMWare ESX Server.B An x445 8-way Xeon MP attached to a DS4300 and running VMWare ESX Server.C An x445 16-way Xeon MP attached to an EXP400 and running VMWare ESX Server.D Four x346 2-ways running VMWare ESX Server.

考题 单选题A customer wants to hold all enterprise data on their DS4000 system.  Several servers were added after they purchased another company.  The servers that have to be run are:       (1)An Oracle database running on a HP-UX server   (2)Several virtual machines running on VMWare ESX server       (3)A Microsoft cluster running Exchange 2000 server   Which of these new servers can be integrated with the DS4000?()A DS4000 storage does not support HP-UX, so the HP-UX server cannot be integrated.All other new servers can be used.B An Exchange cluster needs local disks, so the DS4000 cannot be used for this.All other new servers can be used.C When equipped with proper HBA’s and subsystem device drivers, all new servers can operate with the DS4000 storage device.D VMWare ESX can use the DS4000 storage; however, the virtual machines running in it will not have access to this storage other than via a virtual disk.All other new servers can be used.

考题 单选题An IBM Business Partner has sold a DS5020 and new IBM SAN switches to replace a customer EMC storage infrastructure. The customer dissatisfaction has arisen during the installation because according to the DS5020 interoperability matrix, two HP Proliant servers running Exchange have FC HBAs that are not supported. Which of the following is the most probable cause of the customer dissatisfaction()A The EMC storage specialist has not participated in the TDA meetingB The FC HBAs are 4 Gbps technologyC The Technical and Delivery Assessment review actions were not executedD The customer should have checked that the HBAs are supported according to the HP storage interoperability matrix

考题 单选题A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

考题 单选题A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()A increase the buffer credits on the HBAsB increase the number of device logins on the ESX serversC additional paths will be required between the servers and storageD multipath option on the ESX servers should be changed to round-robin

考题 单选题A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()A Virtual EthernetB Micro-PartitioningC Virtual I/O ServerD Capped and uncapped partitions

考题 单选题A customer is considering replacement of twenty older 4U and 6U rack-based servers with one IBM x366 Server running VMWare ESX attached to one DS4300.  Which of the following represents a reduction in Total Cost of Ownership (TCO) for the customer?()A Reduction in operating system software licensing and application costsB Reduction in floor space and hardware cost savingC VMWare is licensed per system so no extra charge for SMP supportD No single point of failure, reducing downtime

考题 单选题A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()A Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionB Add iSCSI cards to the servers and direct attach them to a DS300 dual controller modelC Use clustered NAS solution with redundant gigabit network connectionsD Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

考题 单选题A customer has a very large number of physical Windows-based servers and no centralized storage. Which technology solution will help the customer to reduce the footprint of their existing server estate?()A z/OS, DS8000, TSMB TSM, LTO-5, VMwareC System x, VMware, XIVD System p, VMware, DS5000