单选题
The furnace of an oil fired boiler should be () before the operating burner is lit.
A
filled with water
B
purged
C
cleared of air
D
None of the above is true
参考答案
参考解析
解析:
暂无解析
更多 “单选题The furnace of an oil fired boiler should be () before the operating burner is lit.A filled with waterB purgedC cleared of airD None of the above is true” 相关考题
考题
In a()boiler the hot gases from the furnace pass gases from the furnace pass water is on the outside.
A.water-tubeB.fire-tubeC.exhaust gasD.composite
考题
When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply
考题
A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off
考题
单选题Before starting a diesel engine, you should always()A
check the pyrometer readingsB
check the crankcase oil levelC
check the fuel oil strainersD
clean the fuel system
考题
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A
in the event of a flame failureB
in the event of a stack fireC
when the water level reach the crown sheetD
when the feed pump discharge pressure drops to a preset minimum
考题
单选题You should frequently compare drum-mounted and remote-reading water level indicators() between these have contributed to failures because of overheating through shortage of water, when a boiler was being oil-fired.A
descriptionsB
discrepanciesC
differentD
deflections
考题
单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().A
yellowish flameB
golden yellow flameC
white flameD
brilliant white flame
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题Before starting a diesel engine that has an engine driven lube oil pump, the engineer should ().A
open the bypass lineB
cut in the lube oil coolerC
pressurize the lube oil systemD
top off the expansion tank
考题
单选题When an auxiliary boiler is panting and emitting black smoke, you should ().A
increase the fuel oil temperatureB
decrease the fuel oil temperatureC
decrease the fuel oil supply pressureD
increase the air supply
考题
单选题The forced draught fan should be started and air passed through the furnace for several minutes to “()” it of any exhaust gas or oil vapors.A
blowB
cleanC
scavengeD
purge
考题
单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()A
cyclone furnace boiler typeB
dry back boiler typeC
water-tube typeD
critical circulation boiler type
考题
单选题A dazzling white burner flame in the boiler furnace indicates ().A
proper combustionB
water in the fuelC
excess airD
cold fuel oil
考题
单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A
cool the furnace to prevent pre-ignitionB
remove explosive vapors from the furnaceC
evaporate accumulated unburned fuel oilD
provide sufficient air in the furnace to allow ignition of the fuel
考题
单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A
excessive purging before lighting offB
insufficient trail for ignition periodC
a faulty transformer in the ignition circuitD
insufficient purging before lighting off
考题
单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A
air or water in the furnaceB
combustion pulsesC
fuel oil pump failureD
flame failure
考题
单选题If in doubt as to the true water level when a boiler is being oil-fired, you should ().A
take no measuresB
extinguish the fire as soon as possibleC
feed water to the boilerD
open the blow down valve
考题
单选题() should be tested and adjusted when the boiler survey is carried out.A
The boiler oil tankB
The steam pipeC
The fire sideD
The safety valves
考题
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A
a burned out solenoid in the oil supply valveB
high temperature excess airC
incorrectly setting the hot-well dump valveD
an incorrectly positioned burner snubber realy
考题
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A
increased fuel consumptionB
increased feed water consumptionC
fuel pump failureD
combustion control system failure
考题
单选题One engine manufacturer recommends heavy fuel oil should not be heated above 80℃ to 95℃ (176 ℉ TO 203℉) before purificationThis upper limit should be observed to ensure against()A
flattening of the bowl neoprene O-ringsB
operation within the explosive rang of the fuelC
excessive purifier operating pressuresD
excessive oil viscosity
考题
单选题One of the main purposes of refractories in a boiler furnace is to()A
help preheat the air for the furnacesB
help preheat the feedwaterC
protect economizer from excessive heatD
prevent excessive furnace heat losses
考题
单选题As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: () (1) secure oil to fires (2) increase feed pump pressureA
(1)B
(1)and(2)C
(2)D
neither(1)nor(2)
考题
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A
check and regulate the water levelB
close the air cock once fires are litC
blowdown the gage glassD
crack the steam stop to assure protective steam flow
考题
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A
10B
7C
4D
1
考题
单选题Which action should be taken when an auxiliary boiler in is operation?()A
Clean all electrical connectionsB
Lift the relief valves by handC
Inspect and clean all solenoid valvesD
Inspect for oil and water leaks
考题
单选题A dazzling white burner flame in the boiler furnace indicates ().A
no combustionB
deposits in the fuelC
excessive air in the fuelD
cold fuel oil