网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
A dazzling white burner flame in the boiler furnace indicates ().
A
no combustion
B
deposits in the fuel
C
excessive air in the fuel
D
cold fuel oil
参考答案
参考解析
解析:
暂无解析
更多 “单选题A dazzling white burner flame in the boiler furnace indicates ().A no combustionB deposits in the fuelC excessive air in the fuelD cold fuel oil” 相关考题
考题
In a()boiler the hot gases from the furnace pass gases from the furnace pass water is on the outside.
A.water-tubeB.fire-tubeC.exhaust gasD.composite
考题
In a ______boiler the hot gases from the furnace pass through the tubes while the water is on the outside.A.water-tubeB.fire-tubeC.exhaust gasD.Composite
考题
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished
考题
One of the main advantages of a graphite-furnace atomizer is that()A、It requires only very small quantities of a sampleB、It requires metal.ions in aqueous solutionC、It does not produce background emission like a flameD、It does not get hot like a flame
考题
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A
in the event of a flame failureB
in the event of a stack fireC
when the water level reach the crown sheetD
when the feed pump discharge pressure drops to a preset minimum
考题
单选题Proper combustion in a boiler would be indicated by ().A
yellowish flameB
golden yellow flameC
white flameD
brilliant white flame
考题
单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().A
yellowish flameB
golden yellow flameC
white flameD
brilliant white flame
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()A
fuel oil supply temperature is normalB
burner electrode is incorrectly positionedC
fuel/air ratio is incorrectD
ignition current is too low
考题
单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A
fuel pump failureB
fan motor failureC
increased feedwater consumptionD
decreased boiler efficiency
考题
单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A
water in the fuel oilB
broken high tension leadsC
incorrect electrode settingD
full fuel pressure at the nozzle
考题
单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A
firing for extended periods in the low fire modeB
overheating, due to waterside depositsC
varying the water level above the crown sheetD
carrying excessive alkalinity in the boiler water
考题
单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()A
cyclone furnace boiler typeB
dry back boiler typeC
water-tube typeD
critical circulation boiler type
考题
单选题A dazzling white burner flame in the boiler furnace indicates ().A
proper combustionB
water in the fuelC
excess airD
cold fuel oil
考题
单选题In a () boiler the hot gases from the furnace pass through the tubes while the water is on the outside.A
water-tubeB
fire-tubeC
exhaust gasD
None of the above is true
考题
单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A
cool the furnace to prevent pre-ignitionB
remove explosive vapors from the furnaceC
evaporate accumulated unburned fuel oilD
provide sufficient air in the furnace to allow ignition of the fuel
考题
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A
steam demand is highB
salinity is highC
safety valve simmersD
burner flame is extinguished
考题
单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().A
waterB
voltageC
fuel pressureD
steam pressure
考题
单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A
air supply is shut offB
fuel supply is shut offC
water supply is shut offD
safety valve lifts
考题
单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A
carbon deposits on the flame scannerB
high fuel oil temperatureC
low fuel oil viscosityD
high steam pressure
考题
单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A
defective solenoid valveB
dirty fuel nozzleC
grounded high tension leadD
faulty ignition cable connector
考题
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A
a burned out solenoid in the oil supply valveB
high temperature excess airC
incorrectly setting the hot-well dump valveD
an incorrectly positioned burner snubber realy
考题
单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A
water in the fuel oilB
excessive cyclingC
high fuel oil pressureD
improper burner maintenance
考题
单选题One of the main purposes of refractories in a boiler furnace is to()A
help preheat the air for the furnacesB
help preheat the feedwaterC
protect economizer from excessive heatD
prevent excessive furnace heat losses
考题
单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A
incorrect electrode settingB
incorrect nozzle positionC
clogged fuel nozzleD
broken high tension lead
考题
单选题As for a oil-fired boiler too much air would indicated by ().A
yellowish flameB
golden yellow flameC
milky flameD
brilliant white flame
考题
单选题The furnace of an oil fired boiler should be () before the operating burner is lit.A
filled with waterB
purgedC
cleared of airD
None of the above is true
热门标签