网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
An administrator performs a Live Partition Mobility operation. After the operation completes, the administrator runs errpt -a. What is the machine ID reported by errpt command?()
A
The machine ID of the machine that logged the error
B
The machine ID of the machine that it is currently running on
C
The administrator defined machine ID in the /etc/machineid file
D
The machine ID of the machine that the operating system was originally started on
参考答案
参考解析
解析:
暂无解析
更多 “单选题An administrator performs a Live Partition Mobility operation. After the operation completes, the administrator runs errpt -a. What is the machine ID reported by errpt command?()A The machine ID of the machine that logged the errorB The machine ID of the machine that it is currently running onC The administrator defined machine ID in the /etc/machineid fileD The machine ID of the machine that the operating system was originally started on” 相关考题
考题
What advantages do WPARs have over LPARs?()A、Security is isolated by the HMCB、Support Live Partition MobilityC、Operating system faults are isolatedD、Reduced system management during upgrades
考题
What does the "allow performance information collection" button do in the Hardware Management Console (HMC) GUI? ()A、 It allows you to get inter partition reports, or cross partition performance activity.B、 It will allow IBM remote technical support to get performance information from the machine.C、 It is effective only on POWER6 and when Live Partition Mobility operations are planned.D、 It will start standard performance monitoring tools when an LPAR boots up, the output will be saved to the /etc/perf directory by default.
考题
Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems?()A、The systems must use internal storage for boot purposes. B、All virtualized ethernet adapters must be numbered below 10. C、The mobile partition's network and disk access must be virtualized. D、Each system must be controlled by a different Hardware Management Console (HMC).
考题
A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility. What other product is required to accomplish this objective? ()A、 HACMP for AIXB、 PowerVM Enterprise EditionC、 IBM Management Edition for AIXD、 Workload Partition Manager for AIX
考题
Which PowerVM feature will allow LPARs to be configured with different configurations of resources?()A、Dynamic LPARsB、LPAR profilesC、Live Partition ConfigurabilityD、Multiple shared processor pools
考题
A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility. Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()A、 PowerVM Standard Edition on POWER6 hardwareB、 PowerVM Standard Edition with POWER5 hardware C、 PowerVM Enterprise Edition with POWER6 hardwareD、 PowerVM Enterprise Edition with POWER5 hardware
考题
A customer has a new Power 720 with PowerVM Standard Edition. They plan to migrate their single-partition POWER5 550 to the new Power 720. How can the customer migrate from the POWER5 550 to the Power 720 with minimal effort and down time?()A、Perform Live Partition Mobility between the two systems.B、Move the boot disks from the old system to the new system.C、Use Tivoli Storage Manager to back up the POWER5 550 and restore on the Power 720.D、Upgrade AIX to the latest level on the POWER5 550 and clone using the mksysb command.
考题
Which of the following interfaces is required to implement Workload Partition Mobility? ()A、 Workload Partitions Manager for AIXB、 Hardware Management Console (HMC) GUIC、 Integrated Virtualization Manager (IVM)D、 Advanced System Management Interface (ASMI)
考题
After making changes to the profile for an LPAR, the administrator asks the operator to bring the LPAR back up into a running state with the new changes. Which of the following is the correct way to do this?()A、Shutdown and activate the partition profileB、Reboot the partition using the reboot commandC、Reboot the partition using the 'shutdown -r' commandD、Right click on the partition profile and select the 'apply changes' option
考题
A customer has systems with AIX 6.1 and 5.3 distributed across two data centers located 8km apart. They want to implement high availability with automated application restart and synchronous data replication between the IBM Systems Storage DS8700 systems which are installed in each datacenter. Which solution addresses the customer requirements?()A、Use the Geographic Logical Volume Manager (GLVM) for MetroMirror, and Live Partition Mobility to automate partition migration upon failureB、Use MetroMirror for the AIX volumes and High Availability Disaster Recovery (HADR) to automate partition migration and restart upon failure.C、Use the Geographic Logical Volume Manager (GLVM) for MetroMirror to replicate the data between the two sites and automate application recovery.D、Use MetroMirror for the AIX volumes, and PowerHA SystemMirror Enterprise Edition to automate failover of MetroMirror pairs and automate application recovery.
考题
Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A、 It has a GUI interface for upgrading system firmware. B、 It creates and manages AIX/Linux and VIOS type LPARs. C、 It can be managed by the Hardware Management Console (HMC). D、 It supports Live Partition Mobility on POWER6 systems and above.
考题
A customer is configuring Live Partition Mobility on two POWER6-based servers, Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()A、 IBM Director connectionB、 Dynamic LPAR Resource Manager (DLRM)C、 Barrier Synchronization Register Device (BSR)D、 Virtual Asynchronous Services Interface (VASI)
考题
An administrator performs a Live Partition Mobility operation. After the operation completes, the administrator runs errpt -a. What is the machine ID reported by errpt command?()A、 The machine ID of the machine that logged the errorB、 The machine ID of the machine that it is currently running onC、 The administrator defined machine ID in the /etc/machineid fileD、 The machine ID of the machine that the operating system was originally started on
考题
A customer is interested in PS700 Blade with 32GB of memory. The Blade will have 4 partitions sharing resources equally. They want the least expensive operating system that supports Live Partition Mobility. Which of the following AIX Editions address their requirement?()A、BasicB、ExpressC、StandardD、Enterprise
考题
An AIX 5.3 customer has a Power 780 in a 2-meter (T42) rack. This rack needs to be moved six inches (15cm) to allow under-floor access. What preparation for moving the rack will result in the least disruption to end-users?()A、Initiate LPAR fallover to backup systems.B、Use Live Partition Mobility to move the LPARs to other systems.C、Use Live Application Mobility to move critical applications to alternate systems.D、Back up all LPARS to a NIM server and restore them to other LPARs on other systems.
考题
单选题An administrator performs a Live Partition Mobility operation. After the operation completes, the administrator runs errpt -a. What is the machine ID reported by errpt command?()A
The machine ID of the machine that logged the errorB
The machine ID of the machine that it is currently running onC
The administrator defined machine ID in the /etc/machineid fileD
The machine ID of the machine that the operating system was originally started on
考题
单选题A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility. What other product is required to accomplish this objective? ()A
HACMP for AIXB
PowerVM Enterprise EditionC
IBM Management Edition for AIXD
Workload Partition Manager for AIX
考题
单选题A customer is configuring Live Partition Mobility on two POWER6-based servers, Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()A
IBM Director connectionB
Dynamic LPAR Resource Manager (DLRM)C
Barrier Synchronization Register Device (BSR)D
Virtual Asynchronous Services Interface (VASI)
考题
单选题A customer has a 32-core Power 770 with 4 AIX partitions and 2 IBM i partitions. They want to improve network availability and allow for concurrent maintenance. What will support the customer requirement at least cost?()A
Build the logical partition infrastructure based on 6 or more VLANs.B
Build the logical partition infrastructure based on two or more IVEs.C
Build the logical partition infrastructure based on Partition Mobility.D
Build the logical partition infrastructure based on redundant VIO Servers.
考题
单选题A customer has two Power 770 systems with 4 enclosures each. Thirty two cores and 1TB of memory are activated on each system. Each system has 3 database partitions and each partition has 10 cores and 300GB of memory. Which solution will provide automated recovery of unplanned outages at least cost?()A
Purchase PowerVM Enterprise Edition.Use System Director to automate Live Partition Mobility to recover from partition failureB
Create additional shared processor partitions as standby nodes.Use PowerHA SystemMirror to activate and use CoD resources when a failover occursC
Purchase an additional 32-core Power 750 with PowerHA SystemMirror Standard Edition.Use the new system as standby node with the XD component of PowerHAD
Purchase an additional Power 770 system.Locate production and standby database partitions on each system.Use DB2 pureScale to provide automated partition monitoring and failover
考题
单选题Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems? ()A
The systems must use internal storage for boot purposes.B
All virtualized Ethernet adapters must be numbered below 10.C
The mobile partition’s network and disk access must be virtualized.D
Each system must be controlled by a different Hardware Management Console (HMC).
考题
单选题In order to support Live Partition Mobility (LPM) for a given LPAR between two Power servers, which type of backing device should be chosen for the storage devices presented from the VIO server to the LPAR?()A
LUN-backed devicesB
File-backed devicesC
Logical volume-backed devicesD
Network Filesystem-backed (NFS) devices
考题
单选题A small IT department is deploying Power 720 servers exploiting virtualization technologies. Each Power 720 will have two partitions, one with 6 cores and one with 2 cores, and both partitions having 32GB of memory each. Live Partition Mobility is being considered at some point in the future. What is the minimum AIX Edition required to support the customer?()A
AIX Basic EditionB
AIX Express EditionC
AIX Standard EditionD
AIX Enterprise Edition
考题
单选题Which of the following interfaces is required to implement Workload Partition Mobility? ()A
Workload Partitions Manager for AIXB
Hardware Management Console (HMC) GUIC
Integrated Virtualization Manager (IVM)D
Advanced System Management Interface (ASMI)
考题
单选题A system administrator is implementing a new 2-way POWER5 server with APV that is to be divided into three partitions. The application groups have requested the following CPU entitlements for the partitions: Partition 1: min = 1.0, max = 2.0, desired = 1.5 Partition 2: min = 1.0, max = 2.0, desired = 1.0 Partition 3: min = 0.1, max = 1.0, desired = 0.8 The administrator immediately finds that the three partitions cannot be started in order to run concurrently. What changes can be made to entitlement configuration to allow all three partitions to be started in order?()A
Change the max on Partition 1 to 1.5.B
Change the desired on Partition 1 to 1.0.C
Change the max and desired on Partition 1 and 2 to 1.0.D
Change the min and desired on Partition 1 and 2 to 0.9.
考题
单选题What does the "allow performance information collection" button do in the Hardware Management Console (HMC) GUI? ()A
It allows you to get inter partition reports, or cross partition performance activity.B
It will allow IBM remote technical support to get performance information from the machine.C
It is effective only on POWER6 and when Live Partition Mobility operations are planned.D
It will start standard performance monitoring tools when an LPAR boots up, the output will be saved to the /etc/perf directory by default.
热门标签
最新试卷