单选题
When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbish
A
Ⅰ+Ⅱ+Ⅲ+Ⅴ
B
Ⅰ+Ⅱ+Ⅲ+Ⅳ
C
Ⅰ+Ⅳ+Ⅴ+Ⅵ
D
Ⅰ+Ⅱ+Ⅲ+Ⅵ
参考答案
参考解析
解析:
暂无解析
更多 “单选题When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ” 相关考题
考题
When an incinerator goes out suddenly, theosupply should be shut off quickly
A.fuelB.sludgeC.airD.fuel and sludge
考题
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished
考题
The oil sludge is burnt in the ______onboard.I’ll show you the ashes.A.boilerB.main engineC.auxiliary engineD.incinerator
考题
In most cases,the mere reception or dumping down of the cargo on the ship ______ involve completion of loading,because the operation of loading involves all that is required to put the cargo in a condition in which it can be carried.A.is notB.has notC.do notD.does not
考题
The oil sludge is burnt in the ______onboarA.I’ll show you the ashes.B.boilerC.main engineD.auxiliary engineE.incinerator
考题
The “cure rate”of many diseases increased dramatically after penicillin was ______ by more doctors.A.put into practice
B.put into effect
C.put into use
D.put into operation
考题
When using IP SLA FTP operation, which two FTP modes are supported? ()A、Only the FTP PUT operation type is supported.B、Active mode is supported.C、Passive FTP transfer modes are supported.D、FTP URL specified for the FTP GET operation is not supported.
考题
A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A、check for a faulty IDE cableB、be sure that the DVD+R is formatted before using itC、check for incompatible mediaD、re-install the DVD burning software
考题
单选题A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A
check for a faulty IDE cableB
be sure that the DVD+R is formatted before using itC
check for incompatible mediaD
re-install the DVD burning software
考题
单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorA
Ⅰ+ⅡB
Ⅰ+ⅢC
Ⅱ+ⅢD
Ⅰ+Ⅱ+Ⅲ
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A
fuel pump failureB
fan motor failureC
increased feedwater consumptionD
decreased boiler efficiency
考题
单选题During waste clothes being charged into an incinerator, the auxiliary burner().A
should be stopped manuallyB
keeps the combustion as usualC
would be cut off by an interlockD
would replace the waste oil burner and keep going on
考题
单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A
water in the fuel oilB
broken high tension leadsC
incorrect electrode settingD
full fuel pressure at the nozzle
考题
单选题When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbishA
Ⅰ+Ⅱ+Ⅲ+ⅤB
Ⅰ+Ⅱ+Ⅲ+ⅣC
Ⅰ+Ⅳ+Ⅴ+ⅥD
Ⅰ+Ⅱ+Ⅲ+Ⅵ
考题
单选题When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbishA
Ⅰ+Ⅱ+Ⅲ+ⅤB
Ⅰ+Ⅱ+Ⅲ+ⅣC
Ⅰ+Ⅳ+Ⅴ+ⅥD
Ⅰ+Ⅱ+Ⅲ+Ⅵ
考题
单选题When the ship is in restricted visibility, the officer in charge of the engineering watch shall ensure that () Ⅰ.Bridge order relating to changes in speed or direction of operation areimmediately implemented Ⅱ.auxiliary machinery used for maneuvering is readily available Ⅲ.permanent air or steam pressure is available for sound signalsA
Ⅰ+ⅡB
Ⅰ+ⅢC
Ⅱ+ⅢD
Ⅰ+Ⅱ+Ⅲ
考题
多选题Which operation requires that you create an auxiliary instance manually before executing the operation?()ABackup-based database duplication.BActive database duplication.CTablespace point-in-time recovery.DNo operation requires the creation of an auxiliary instance.
考题
单选题Emergency generator is installed on board mainly to ()A
connect to the busbar when the load increasingB
supply power specially to charging panelC
be put into operation during the ship arriving at or leaving portD
ensure the power supply to critical equipment after the main switchboard out of power
考题
单选题Which of the following actions should normally be taken during each watch when the auxiliary boilers is in operation?()A
clean the flame scanner photocell windowB
Inspect and clean all solenoid valvesC
lift the safety valves by handD
Inspect for oil or water leaks
考题
单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().A
furnace to be re-purgedB
electric charge to buildup in the igniterC
fuel pump to restartD
drum level to stabilize
考题
单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A
defective solenoid valveB
dirty fuel nozzleC
grounded high tension leadD
faulty ignition cable connector
考题
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A
a burned out solenoid in the oil supply valveB
high temperature excess airC
incorrectly setting the hot-well dump valveD
an incorrectly positioned burner snubber realy
考题
单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A
water in the fuel oilB
excessive cyclingC
high fuel oil pressureD
improper burner maintenance
考题
单选题Concerning the incinerator’s operation, which of the following is not correct?()A
Scavenging time should be more 30 seconds before ignitingB
The temperature of sludge tank is 80~100℃C
First igniting the incinerator with diesel oil, when the temperature of health is about 600℃, the sludge oil drawn inD
The ash can be dumped into sea when the distance is more than 3 miles from land
考题
单选题When the incinerator is stopped, which of the following is wrong?()A
After stopping supplying sludge oil, the value and pipe should be flushed by flushed by diesel oil and the incinerator continue burning for 10 minutesB
Close auxiliary burner firstly and then close main burnerC
After stopping fuel, restoring the position of main fuel supply valveD
Stop blower as soon as stopping supplying fuel oil
考题
单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().A
furnace to be re-purgedB
electric charge to buildup in the igniterC
fuel pump to restartD
dram level to stabilize
考题
单选题Which action should be taken when an auxiliary boiler in is operation?()A
Clean all electrical connectionsB
Lift the relief valves by handC
Inspect and clean all solenoid valvesD
Inspect for oil and water leaks