In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().
A

fresh water

B

vapor

C

mixture

D

liquid


参考答案

参考解析
解析: 暂无解析
更多 “单选题In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().A fresh waterB vaporC mixtureD liquid” 相关考题
考题 If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

考题 If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 Which method is used to supply inert gas from a flue gas system to the cargo tanks?A.Exhaust gas pressure from the stackB.High capacity fanC.Inert gas compressorD.Natural aspiration

考题 Which statement about inert gas pressures in a cargo tank is TRUE ________.A.The pressures of the inert gas in the tank may create excessive pressure at the pump while dischargingB.Gas pressures should be maintained at the highest permissible level throughout the discharging processC.High gas pressures may cause pyrophoric oxidation in the tankD.High gas pressures may cause loss of suction when stripping

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题Which will cause the high pressure cutout to stop the compressor in a R-22 system?()A Condenser leakageB A shortage of liquid refrigerantC Excessive frost on the evaporatorD Not enough condenser cooling water

考题 单选题Refrigerant enters the condenser as a ().A high pressure liquidB low pressure vaporC high pressure vaporD low pressure liquid

考题 单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A increase the flow of the cooling water through the condenserB adjust the high pressure cutout to maintain the desired pressureC open the hot gas bypass temporarily to reduce capacityD purge non-condensable gases to reduce the excess pressure

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().A fresh waterB vaporC mixtureD liquid

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().A liquid strainerB refrigerant inlet of the condenserC inlet side of the evaporatorD suction side of the compressor

考题 单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()A too much cooling water going through the condenserB not enough refrigerant in the systemC a leak in the evaporator coilsD no enough cooling water going through the condenser

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题A pressure drop through the refrigerant liquid line may cause ().A solenoid valve to seizeB compressor to huntC formation of flash gas in the liquid lineD expansion valve to freeze open

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve

考题 单选题If the head pressure is too high,()A the relief valve should open before the high-pressure cutoutB the relief valve should open and let excess refrigerant go to receiverC the high-pressure cutout switch should operate before the relief valve opensD close in on the suction valve

考题 单选题Excessively warm water leaving condenser may be caused by()A fouled tubes in shell and tube condenserB too little or too warm condenser waterC air or non-condensable gas in systemD overcharge of refrigerant

考题 单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().A compressorB condenserC throttle valveD evaporator

考题 单选题The thermal expansion valve reacts directly to the ()A temperature in the space being cooledB liquid refrigerant pressure at the solenoid valveC pressure drop across the evaporator coilsD refrigerant gas superheat at the coil outlet

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题In a refrigeration system, which of the following statements describes the actions occurring when a solenoid valves, used in conjunction with an unloader head is energized?()A The solenoid valves directs high pressure gas to the valve lifting device raising the suction valve off its seat and causing one specific cylinder to become unloadedB The solenoid valves directs high pressure gas to the underside of the unloading piston, causing it to rise and allowing the recirculating ports to be openedC When the solenoid valve becomes energized, the valve ports become closed, allowing discharge pressure to build up above the piston, shifting it and causing it to unloadD The solenoid valve allows the refrigerant to pass from the suction chamber to the top of the unloader piston, causing the piston to lift and unload the cylinder

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve