Low compressor head pressure in a refrigeration system can be caused by().
A
insufficient condenser cooling water
B
excessive condenser cooling water
C
air in the refrigeration system
D
excessive refrigerant in the system
参考答案
参考解析
解析:
暂无解析
更多 “单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system” 相关考题
考题
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
考题
Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor
考题
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A
pressurestatB
high pressure cutoutC
solenoid valveD
low pressure cutout switch
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A
purge the condenser if the waterside is dirtyB
check for proper water flow through the condenserC
increase the high pressure cutout settingD
reduce the cooling water flow
考题
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A
system was overcharged with refrigerantB
high pressure switch was improperly adjustedC
expansion valve strainers were fouledD
suction valves were leaking slightly
考题
单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A
system was overcharged with refrigerantB
system was low on refrigerantC
suction valves were leaking slightlyD
relief valve was leaking slightly
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A
always be wide open when the compressor restartsB
continue to operate as if the system were in operationC
remain open until evaporator pressure equalizes, then close until the compressor restartsD
always be completely closed until the compressor restarts
考题
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A
the compressor short cycling on high pressure cut out switchB
high suction pressureC
high head pressureD
bubbles in the sight glass
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A
Condenser and thermal expansion valveB
King and solenoid valvesC
Compressor and thermal expansion valveD
Condenser and solenoid valve
考题
单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A
refrigerant overchargeB
overfeeding by the expansion valveC
a restricted suction strainerD
due to short cycling of the compressor
考题
单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A
oil foaming in the compressorB
higher than normal suction and discharge pressures with a higher box temperatureC
higher than normal discharge pressure with a normal box temperatureD
the compressor to run continuously
考题
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A
system is overcharged with refrigerantB
system is low on refrigerantC
discharge valves are leaking excessivelyD
discharge valves are leaking slightly
考题
单选题One cause of high head pressure occurring in a refrigeration system can be ().A
insufficient cooling water flow to the condenserB
a low refrigerant charge in the systemC
the liquid valve is open too muchD
high evaporator superheat
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题An increase in the heat load to a refrigeration system will cause ().A
the suction pressure to decreaseB
the suction temperature to increaseC
increased ice formation on the evaporator coilD
excessive short cycling of the compressor
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题Sweating of the refrigeration system compressor crankcase is caused by ().A
too much superheatB
insufficient superheatC
suction pressure too lowD
excessive refrigerant returning to the compressor
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
考题
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A
The condenser and the expansion valveB
The king valve and the solenoid valveC
The compressor and the expansion valveD
The condenser and the solenoid valve