单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


参考答案

参考解析
解析: 暂无解析
更多 “单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system” 相关考题
考题 If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A broken valve springsB tight drive beltsC high line voltageD air in the system

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A the compressor short cycling on high pressure cut out switchB high suction pressureC high head pressureD bubbles in the sight glass

考题 单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve