网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
“Flooding back” is a condition where the liquid refrigerant ().
A
vaporizes in the condenser
B
reaches the compressor through the suction line
C
flashes in the liquid line
D
condenses in the receiver
参考答案
参考解析
解析:
暂无解析
更多 “单选题“Flooding back” is a condition where the liquid refrigerant ().A vaporizes in the condenserB reaches the compressor through the suction lineC flashes in the liquid lineD condenses in the receiver” 相关考题
考题
To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid
考题
If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease
考题
单选题A positive displacement pump is that where the volume of the pump chamber is alternately increased to () and then decreased to ().A
draw the liquid in;force the liquid outB
force the liquid out;draw the liquid inC
suction;drawD
deliver;outlet
考题
单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A
Proper refrigerant chargeB
Faulty expansion valveC
Insufficient refrigerantD
Solenoid valve stuck open
考题
单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A
a shortage of refrigerant in the systemB
air in the systemC
an accumulation of liquid refrigerant in the crankcaseD
a shortage of oil in the crankcase
考题
单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A
restriction in refrigerant pipingB
air and non-condensable gases in the condenserC
water in the refrigerantD
flooding back of liquid refrigerant from the evaporator
考题
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A
maintain adequate coil back pressureB
prohibit flashing in the liquid lineC
reduce refrigerant volume in the systemD
reduce compressor discharge line loading
考题
单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A
too much refrigerant in the systemB
oil entrained in the refrigerantC
less than a full charge of refrigerant in the systemD
ice crystals forming in the refrigerant
考题
单选题A pressure drop through the refrigerant liquid line may cause ().A
solenoid valve to seizeB
compressor to huntC
formation of flash gas in the liquid lineD
expansion valve to freeze open
考题
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A
refrigerant boiling out of solution from the lube oilB
liquid refrigerant flooding the compressor and systemC
lube oil viscosity being reduced by refrigerant dilutionD
compressor suction pressure suddenly increasing
考题
多选题Which three are true regarding the use of outer joins? ()AYou cannot use IN operator in a condition that involves an outerjoin.BYou use (+) on both sides of the WHERE condition to perform an outerjoin.CYou use (*) on both sides of the WHERE condition to perform an outerjoin.DYou use an outerjoin to see only the rows that do not meet the join condition.EIn the WHERE condition, you use (+) following the name of the column in the table without matching rows, to perform an outerjoin.FYou cannot link a condition that is involved in an outerjoin to another condition by using the OR operator.
考题
单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().A
evaporatorB
compressorC
expansion valveD
condenser
考题
单选题Moisture in the refrigerant may ().A
freeze on the expansion valve seat and reduce the flow of liquid refrigerantB
emulsify the oil in the condenserC
freeze in the king valveD
clog the oil trap
考题
单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A
suction service valve as a vaporB
suction service valve as a liquidC
discharge service valve as a vaporD
charging valve as a liquid
考题
单选题“Flooding back” is a condition where the liquid refrigerant ().A
vaporizes in the condenserB
reaches the compressor through the suction lineC
flashes in the liquid lineD
condenses in the receiver
考题
单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()A
At the designed operating temperature, the liquid refrigerant charge has changed to a vaporB
The liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityC
The sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureD
The sensing bulb is never emptied of liquid refrigerant under normal operating conditions
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题The principal purpose of sub-cooling liquid refrigerant prior to its entering the expansion valve is to ().A
increase the refrigerating effect, by decreasing the amount of flash gasB
allow the refrigerant to enter the throttling device in a saturated conditionC
increase the refrigerating effect by increasing the amount of flash gasD
minimize the temperature drop of the liquid as it passes through the solenoid valve to the outlet side
考题
单选题Sub-cooling is a method of reducing the temperature of the liquid refrigerant below its ().A
freezing pointB
floc pointC
condensing temperatureD
compression temperature
考题
单选题Of a kind of liquid is used to cool the diesel engine, it is invariably called ()A
lubricantB
coolantC
combustion productD
second refrigerant
考题
单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().A
re-adjust the discharge pressureB
clean the expansion valve screenC
add refrigerantD
adjust the expansion valve
考题
单选题If liquid refrigerant accidentally comes in contact with the eyes, () immediately.A
rub the eyesB
irritate the eyesC
wash the eyes with a heavy boric acid solutionD
obtain medical help
考题
单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().A
condition of the expansion valveB
moisture in the systemC
condition of the compressor suction valvesD
condenser temperature
热门标签
最新试卷